background image

Web: www.tinker-rasor.com 

E-mail: [email protected]

– 9 –

 

P

RODUCT 

I

NSTRUCTIONS

 

directions.  the exact center of the metallic object shall be 
determined  by the “null” or minimum signal (FIGURE 12).

 

MAINTENANCE 

Battery life expectancy under normal use exceeds one year.   To 
replace batteries on locators with serial number through 56455, 
remove four brass screws on the edges of both panels; for 
access to battery compartment on locators with serial number 
56456 and higher, back off single screw on battery access door at 
the rear of each instrument until door opens.  Replacement:  12 
each “C” Alkaline Batteries. 

Note:  “C” cell conversion kits are available for older models

.

 

SERVICE 

Your  Detectron  Model  505  has  been  carefully  inspected  and  tested.  The  possibility  of  the 
instrument requiring servicing other than battery replacement is extremely remote; however, the 
mechanical design permits a qualified technician to quickly diagnose and correct any malfunction.  
Circuit boards are plug-in type, designed for easy servicing.  For quantity users, we suggest low 
cost replacement circuit boards be carried in stock.  However, they, like all other parts, are readily 
available from factory. 

The DETECTRON MODEL 505 

Carries a Full One Year

WARRANTY

It  is  warranted  to  be  free  from  mechanical  and  electrical  defects  due  to  faulty 
workmanship and materials.  Any locator proven defective under this warranty within one 
year from date of sale to original purchaser will be repaired or replaced free of charge at 
our plan; batteries and transportation charges excepted. 

Manufacturer assumes no responsibility other than to the original purchaser for repairs 
made outside our factory. 

009-248 

DIVISION OF TINKER & RASOR 

2828 FM 758, NEW BRAUNFELS, TX 78130 TEL: (830) 253-5621 

www.detectron.com 

Summary of Contents for 505 GO-FER

Page 1: ...Handle Mounting Receptacle Threaded receptacle for mounting transmitter on carrying handle M Battery Test Lamp Gives lighted indication of Transmitter battery condition N Conductive Inductive Switch a...

Page 2: ...cellent results THEORY OF OPERATION DETECTRON PIPE CABLE LOCATORS provide in practical form an electronic instrument for locating and accurately pinpointing concealed metal objects such as metallic pi...

Page 3: ...overn the amount of signal indication received It will originally be noted that the signal indication over a buried pipe is very wide By reducing the setting of the SENSITIVITY control the width of in...

Page 4: ...hod is best for a given situation and by using one of the suggested methods it is possible to solve practically any pipe locating problem The operation of a pipe locator conductivity is appreciably th...

Page 5: ...ER is parallel to pipe and over it 4 Very strong when TRANSMITTER is parallel to pipe and close to it Amount of signal detected by RECEIVER Fig 2 1 Minimum signal when RECEIVER is perpendicular to pip...

Page 6: ...UT HANDLE Both the RECEIVER and TRANSMITTER are held in a vertical position and parallel to the assumed location of the sought pipe The two operators proceed in unison from the curb line toward the op...

Page 7: ...general pipeline location a very pronounced null or minimum signal will be noted The point of the null is the exact center of the pipeline FIGURE 6 DETERMINING THE DEPTH OF A PIPE INDUCTIVELY WITH OUT...

Page 8: ...depth of the pipe After depth of pipe is determined subtract the depth distance from indicated dead end for accurate location of pipe end The use of the instrument conductively is identical to that d...

Page 9: ...ervicing other than battery replacement is extremely remote however the mechanical design permits a qualified technician to quickly diagnose and correct any malfunction Circuit boards are plug in type...