Timpex ECO 100+ User Manual Download Page 6

 
ECO 100+ Automatic Regulation of Burning 
 

4

 

MOBILE APP DOCUMENTATION 

4.1

 

Main Screen 

 

Barva aplikace 
Background color 

The app background alternates between four colors based on current firebox temperature: 
 

 

yellow   

- firebox temperature below optimum 
- should only show when starting a fire or when down to hot coals 

 

green        

- firebox at optimum temperature 
- best fuel efficiency 

 shows a green leaf icon 

 

red 

 

- firebox overheated 
- excess energy lost via chimney 

 shows a chimney icon 

Grey colour means cold firebox (firebox at room temperature, no fire). 

Summary of Contents for ECO 100+

Page 1: ...USER MANUAL Automatic Regulation of burning for fireplaces and stoves ECO 100...

Page 2: ...e App with the ECO 100 Control Unit 4 4 MOBILE APP DOCUMENTATION 5 4 1 Main Screen 5 4 2 Menu 7 5 CONTROL UNIT SOUND ALERTS 8 6 USING AUTOMATIC REGULATION OF BURNING 9 6 1 Start 9 6 2 Refueling 9 7 SA...

Page 3: ...heating system including the chimney The ECO 100 can detect overheating and inform the user to add less fuel in the next refueling The mobile app informs the user about the current status throughout t...

Page 4: ...onal external components depending on device type Signals when refueling is needed Provides information on heating system performance 2 MOBILE APP REQUIREMENTS 2 1 Android Devices Android 5 Lollipop o...

Page 5: ...rches for your specific ECO 100 control unit only near your position 4 Once launched the app starts an automatic search for nearby ECO 100 devices Once the search completes the app will show a list of...

Page 6: ...based on current firebox temperature yellow firebox temperature below optimum should only show when starting a fire or when down to hot coals green firebox at optimum temperature best fuel efficiency...

Page 7: ...e Menu below Burning phase circle Maximum burn point A Refueling point with sound alert B START button Press to start a new automatic burn control cycle Details see Start Burn Control below SDS activi...

Page 8: ...n is inactive The EAI shutter can then be moved manually using its attached handle or the stove s own shutter handle can be used When automatic control is off the Main Screen shows MAN for manual mode...

Page 9: ...We recommend checking for app updates regularly through Google Play Android or the App Store Apple or setting the app to auto update Unit Settings Settings for authorized service technicians The entra...

Page 10: ...ition B Always adhere to fuel quantity and type recommendations provided by the heating system manufacturer 7 SAFETY INSTRUCTIONS 7 1 What to Do in Case of Power Outage In the event of mains power fai...

Page 11: ...ce a burn control cycle has started the system opens the EAI shutter to 100 and subsequently gradually closes it in accordance with the selected control curve program 8 2 Automatic Regulation Mode Onc...

Page 12: ...working Automatic regulation is turned off in the app Settings Turn it on in menu Current exhaust temperature readout shows The exhaust temperature readout only shows when flue gas is warmer than the...

Page 13: ...ns before performing any maintenance on the device In the event of malfunction please return the device to the distributor along with a detailed description of the problem 11 TECHNICAL DATA Control un...