User  Manual-VN1 

 

 

Version C July 2020 

5  of  23 

 
 
 

 

Be sure the actuator is connected to a main electricity supply/transformer with the correct voltage, 
specified on the actuator label. 

 

Be sure that the connection bolts are secured safely and can withstand the wear.   

 

Stop the actuator immediately if anything unusual is observed. 

 

Ensure there is no side load present on the actuator. 

 

Only use the actuator within the specified working limits. 

 

Refrain from having any contact with the actuator.   

 

Equipment power off 

1.8.3

 

Switch off the main supply to prevent any unintentional operation. 

 

Regularly check for extraordinary wear. 

 

Duty cycle 

1.8.4

 

The standard duty cycle is 10%. 

 

If the product is customized, please refer to the approval drawings. 

 

Temperature 

1.8.5

 

The operating temperature range is -15°C ~+50°C.The operational temperature range at full 
performance is +5°C ~+45°C.  

 

Summary of Contents for VN1

Page 1: ...User Manual VN1 Version C July 2020 1 of 23 Version C User Manual VN1...

Page 2: ...erature 5 1 8 5 2 Installation 6 Mechanical installation 6 2 1 Mounting notice 6 2 1 1 Safety Instructions 7 2 1 2 Electrical installation 10 2 2 Important notice 10 2 2 1 Extension power cable 11 2 2...

Page 3: ...2 Please allow qualified mechanical and electrical professionals perform all installation maintenance and replacement of the TiMOTION products Please keep the products away from people who do not have...

Page 4: ...t the actuator is or shall be a part of Adhere to the information contained in this user manual and on the product label Never exceed the performance limits stated herein Be sure the actuator is not i...

Page 5: ...here is no side load present on the actuator Only use the actuator within the specified working limits Refrain from having any contact with the actuator Equipment power off 1 8 3 Switch off the main s...

Page 6: ...ded at both ends of the attachments Do not mount the actuator with the pins in different rotated angles this could cause stress on the nut during operation The load should act along the stroke axis of...

Page 7: ...o the opening width the opening area the opening time the opening speed of the window the temperature range of the drives external devices and cables as well as the cross section of the connecting cab...

Page 8: ...by crush and shear points Side hung Bottom hung Roof windows Louver windows Crush and shear points To avoid injuries crushing and shear points between casement and frame must be secured against entrap...

Page 9: ...ontrol Unit for the drive The main supply lines 230 V 400 V AC need to be protected separately Damage to main supply lines of drives with plug connectors may only be re placed by the manufacturer or q...

Page 10: ...ase ensure it is able to withstand the peak of high voltage To reduce the chance of interference refrain from placing signal cables along power cables Use a two wire system to prevent ground loop Plea...

Page 11: ...ing leads It is important to use the extension power cable from the DC source with proper size to avoid a significant voltage drop The further away the DC source is the larger the extension cable may...

Page 12: ...or starts to work there is an inrush current to the motor that will be less than 0 2 seconds up to four times the rated current Please select a power supply that is able to withstand the inrush curren...

Page 13: ...nd warnings If there is a different system request not listed in the following table please contact TiMOTION for further discussion Voltage System Connection description A DC Single Stable DC power su...

Page 14: ...ble DC Following actuator motor voltage output power supply with sufficient power b Switch DPDT DC switch to control the power polarity of motor with sufficient current resistance check the spec code...

Page 15: ...C power source b Switch The SPDT AC switch controls the power polarity of the motor with current resistance be sure to check the spec code of VN1 for most current information c System Single actuator...

Page 16: ...VN1 Version C July 2020 16 of 23 e Wiring illustration SPDT AC switch Black EXT Blue N Grey RET Window sealed indicator The lamp is off when all actuators are closed Limit switch NC Potential free Op...

Page 17: ...switch controls the power polarity of the motor with current resistance be sure to check the spec code of VN1 for most current information c System Multiple actuators operate simultaneously recommende...

Page 18: ...sion C July 2020 18 of 23 e Wiring illustration SPDT AC switch Black EXT Blue N Grey RET Window sealed indicator The lamp is off when all actuators are closed Limit switch NC Potential free Optional L...

Page 19: ...User Manual VN1 Version C July 2020 19 of 23 3 Product specifications 2D drawings 3 1 A VN1 DC version without T smart sync function Cable exit Position 1 Cable exit Position 2...

Page 20: ...User Manual VN1 Version C July 2020 20 of 23 Ordering key 3 2 Please contact your TiMOTION sales engineer for the latest revision ordering key...

Page 21: ...rload in the application Align or reduce the load Try running the actuator without load Actuator cannot lift full load or motor runs too slowly Insufficient power supply Check the power supply is prop...

Page 22: ...ly and the external control unit if any Please make sure the power supply polarity is properly connected otherwise you could damage the actuator Communication wires are not properly connected Check th...

Page 23: ...he actuator is running After everything is connected supply power to all actuators at the same time Then wait 10 seconds before the Run In Run Out signals are activated Signal cable damaged or removed...

Reviews: