8.

 

Restore Factory Setting 

(1)

 

Refer to Chapter 2-Reset: after the “beep” sound, press 

  and 

  buttons together for 15 seconds, the 

control box will twice make a “beep” sound. 

(2)

 

The settings below will restore to the original factory settings: 

 

Memorized position 

 

Desk starting height 

 

Upper and lower height limit 

 

T-touch or TCS1 sensitivity 

9.

 

Error Codes 

The digital display shows the error codes below to suggest the issues that users may encounter during the 

operation. 

(Note 4)

 

Error code 

Descriptions 

000 

Resetting 

E00 

Not reset completely 

E01 

Overuse protection 

E02 

Unbalance protection 

E03 

Anti-collision 

E04 

T-touch Protection 

E11 

M1 Motor over-current protection 

E12 

M2 Motor over-current protection 

E13 

M3 Motor over-current protection 

E21 

No Hall sensor from M1 

E22 

No Hall sensor from M2 

E23 

No Hall sensor from M3 

E31 

No current from M1 

E32 

No current from M2 

E33 

No current from M3 

Note 4: Some control boxes may not support this function. 

 

 

Summary of Contents for TDH8P

Page 1: ...Hand Control Programming TDH8P Version 3 August 2021 1 of 11 20210811 User Manual HandControl Programming TDH8P...

Page 2: ...erface Guide 4 2 Reset 5 3 Adjusting the Height 6 4 Setting the Memorized Position 6 5 Setting the Upper and Lower Height Limit 7 6 Presetting the Desk Starting Height 8 7 Switching Metric and Imperia...

Page 3: ...claimer This user manual is ONLY for generic TiMOTION products Manufacturers may have altered product settings causing them to differ from this user manual Please contact the manufacturer for a revise...

Page 4: ...Hand Control Programming TDH8P Version 3 August 2021 4 of 11 1 User Interface Guide 3 digit height display Memory setting buttons Up and down buttons Up and down buttons Memory setting buttons...

Page 5: ...nue pressing the buttons until both columns are in the lowest position When finished with the reset the control box will make a beep sound and the buttons can be released 2 When finished with the rese...

Page 6: ...emory positions How to memorize a position 1 Adjust the desk to the desired height 2 Press the preferred memory button 1 2 3 or 4 with either or for 2 seconds Once the display shows P1 or P2 or P3 or...

Page 7: ...is being set 2 Repeat instructions 2 4 above to disable the upper limit setting C Setting the lower height limit 1 Adjust the desk to the preferred lower height limit 2 Press and buttons together for...

Page 8: ...e desk reaches its lowest position and then release button Re press button again for 5 seconds and the digital display will flash for 10 seconds 2 Adjust the starting height number with the or button...

Page 9: ...s 2 The digital display will show C I If no further instruction is input within 5 seconds the system reverts to normal operation mode How to choose a metric unit Press memory button 2 the digital disp...

Page 10: ...des The digital display shows the error codes below to suggest the issues that users may encounter during the operation Note 4 Error code Descriptions 000 Resetting E00 Not reset completely E01 Overus...

Page 11: ...no buttons are pressed within 25 seconds Press any button to light up the display again The system goes into 0 1W standby mode Note 5 if no buttons are pressed within 30 seconds Long pressing any butt...

Reviews: