background image

 

Hand Control Programming- TDH5PR 

 

 

 

Version 3 August 2021 

10  of  10 

10 

 

10.

 

Power Saving Function - Waking Up the 

Control 

 

 

The digital display automatically turns off if no buttons are pressed within 25 seconds. Press any button 

to light up the display again.   

 

The system goes into <0.1W standby mode 

(Note 5)

 if no buttons are pressed within 30 seconds. Long 

pressing any button will wake up the system and show desk height on the digital display.   

 

Note 5: It depends on the control box whether it will support 0.1W standby mode or not. 

Summary of Contents for TDH5PR

Page 1: ...Hand Control Programming TDH5PR Version 3 August 2021 1 of 10 error codes 20210811 User Manual HandControl Programming TDH5PR...

Page 2: ...terface Guide 4 2 Reset 5 3 Adjusting the Height 6 4 Setting the Memorized Position 6 5 Setting the Upper and Lower Height Limit 7 6 Presetting the Desk Starting Height 8 7 Switching Metric and Imperi...

Page 3: ...sclaimer This user manual is ONLY for generic TiMOTION products Manufacturers may have altered product settings causing them to differ from this user manual Please contact the manufacturer for a revis...

Page 4: ...Hand Control Programming TDH5PR Version 3 August 2021 4 of 10 1 User Interface Guide Connection port to TWD1 or TCS1 3 digit height display Memory setting buttons Up and down buttons...

Page 5: ...nue pressing the buttons until both columns are in the lowest position When finished with the reset the control box will make a beep sound and the buttons can be released 2 When finished with the rese...

Page 6: ...4 memory positions How to memorize a position 1 Adjust the desk to the desired height 2 Press preferred memory button 1 2 3 4 with either or for 2 seconds once the display shows P1 or P2 or P3 or P4...

Page 7: ...being set 2 Repeat instructions 2 4 above to disable the upper limit setting C Setting the lower height limit 1 Adjust the desk to the preferred lower height limit 2 Press and buttons together for le...

Page 8: ...er 10 seconds the display will stop flashing and this will confirm that you have successfully set the starting height 7 Switching Metric and Imperial Unit 1 Press memory buttons 1 2 and 4 for 5 second...

Page 9: ...tivity 9 Error Codes The digital display shows the error codes below to suggest the issues that users may encounter during the operation Note 4 Error code Descriptions 000 Resetting E00 Not reset comp...

Page 10: ...no buttons are pressed within 25 seconds Press any button to light up the display again The system goes into 0 1W standby mode Note 5 if no buttons are pressed within 30 seconds Long pressing any butt...

Reviews: