Timing Solutions TSC 4033A Operation And Maintenance Manual Download Page 5

 

  

  

4033A Operations and Maintenance Manual 

 

 

1: Introduction  

 

Note

 

FIRST READ THIS MANUAL THROUGHLY! 

This is especially true for the sections regarding 

Safety 

and 

Installation. 

 

1.1 Symbols 

 

These symbols appear throughout the manual as well as on the unit itself

.

 

 

Note

This symbol means the following information is a note that gives you 
important information that may affect how you use the 4033A.

 

 

Caution, refer to manual. Read all instructions in Manual 
before using this product.   

 

CE marking, attesting compliance to applicable European 
Directives 

 

               Caution – Risk of Electrical shock 

 

Fuse symbol 

 
 

Summary of Contents for TSC 4033A

Page 1: ...Operations and Maintenance Manual 1 TSC 4033A 1 x 15 5 Volt Pulse Distribution Amplifier Operations and Maintenance Manual 4775 Walnut Street Suite 1B Boulder CO 80301 USA www timing com Phone 303 939...

Page 2: ...ier Operations and Maintenance Manual Copyright 2004 Timing Solutions Corporation Timing Solutions is a trademark of the Timing Solutions Corporation Other product and company names may be trademarks...

Page 3: ...e 4033A 14 3 1 Accessing the System 14 3 2 Checking System Status 14 3 2 1 Checking Alarms and Input Frequency 14 3 2 2 Checking Model Number and Software Version 15 3 3 Understanding Alarm Output 15...

Page 4: ...This page intentionally left blank...

Page 5: ...bols appear throughout the manual as well as on the unit itself Note This symbol means the following information is a note that gives you important information that may affect how you use the 4033A Ca...

Page 6: ...TWORK DO NOT CONNECT TO TELECOM CONNECTIONS THAT CARRY HAZARDOUS VOLTAGES 101010 Serial port connection DO NOT CONNECT TO TELECOM CONNECTIONS THAT CARRY HAZARDOUS VOLTAGES Earth terminal symbol Used t...

Page 7: ...ow to replace fuses and verify operational problems Chapter 5 Warranty and Shipping Information on page 17 explains how to contact Timing Solutions Corporation for warranty service and provides shippi...

Page 8: ...green LED status for the input and green red for all output signals as well as indicating an input of 1 PPS DC IRIG or Other A green LED on the front panel also provides power status Figure 1 shows th...

Page 9: ...rify that input line voltage and current capacity are within specifications before turning on power to the unit Disconnect all sources of input power before removing the top cover of this unit Operati...

Page 10: ...ounting screws Screwdriver for the rack mount screws and slide as needed 2 4 3 Making Connections 2 4 3 1 Input Power AC INPUT POWER The input power to the unit is supplied through a detachable 3 pron...

Page 11: ...ult IP address of 0 0 0 0 which enables DHCP If the network has a DHCP server it will automatically assign the unit an IP address gateway address and subnet mask when the unit starts up To monitor mul...

Page 12: ...ress dialog box 5 Type the new IP address for the appropriate Hardware or Ethernet address and click Set IP address The new IP address appears in the Lantronix DeviceInstaller window 6 Test the IP add...

Page 13: ...ce Manual 13 Note If you move the 4033A to a different network hub after setting up the static IP address the host computer may not be able to make a connection You may need to release the IP address...

Page 14: ...e of input signal To check system status Type S case sensitive You do not need to type a carriage return or line feed The system returns Scccc llll x r n where cccc is current alarms llll is latched a...

Page 15: ...stem returns Vxx r n where xx is the software version Example V80 Sending an I command will turn on the three front panel input LEDs for 2 seconds before returning to normal operation This provides th...

Page 16: ...cement fuse for a standard IEC 320 power entry module with fuse 5 x 20 mm 1 A 250 V Time lag fuse To replace a fuse 1 Disconnect the power cable from the back of the 4033A 2 Using a small screwdriver...

Page 17: ...4033A Operations and Maintenance Manual 17 This page intentionally left blank...

Page 18: ...Corporation 4775 Walnut Street Suite 1B Boulder CO 80301 USA 5 2 Shipping Information If you need to ship this system for any reason including returning equipment to Timing Solutions for warranty serv...

Page 19: ...4033A Operations and Maintenance Manual 19 This page intentionally left blank...

Page 20: ...uipment for Measurement Control and Laboratory Use Part 1 General Requirements EMC EN61326 2000 Electrical Requirements for Electrical Equipment for Measurement Control and Laboratory Use Part 1 Gener...

Page 21: ...4033A Operations and Maintenance Manual 21 This page intentionally left blank...

Page 22: ...eed 10 of nominal supply voltage Power Inlet Type IEC 60320 sheet C14 Power Supply Cord Set 18 AWG 0 75 mm2 minimum Power Mains Fuse 2 250V 1A Time lag 5x20 mm Signal Input Impedance 50 Logic one 2 4...

Page 23: ...ment suitable for continuous operation Table 4 lists the environmental specifications for the 4033A Table 4 Environment specifications Item Temperature Relative Humidity Altitude In Use 0 C to 50 C 0...

Page 24: ...P Dynamic Host Configuration Protocol ESD electrostatic discharge LED light emitting diode LSB least significant bit MSB most significant bit PDF portable document format PWA printed wiring assembly R...

Page 25: ...checking 13 input power connecting 10 input signal connecting 10 installing a 4033A 10 instructions packing 17 safety 9 IP address assigning 11 L LAN connecting 11 LAN port symbol 6 Lantronix DeviceIn...

Page 26: ......

Page 27: ...4033A Operations and Maintenance Manual 1...

Reviews: