background image

 

   

Installation of DFF3D Multibeam Sounder

 

© 1985-2018 

Nobeltec

 - 

[email protected]

 - 1 

 

Installation of DFF3D Multibeam Sounder 

The "DFF3D

 

and “PBG” Modules need to be unlocked prior to 

configuring the Furuno DFF-3D in 

TZ Professional. 

 

Computer Setup 

The DFF-3D connects to the PC through an Ethernet connection (100Base-T). All Furuno Ethernet sensors (including Ethernet sounders) only operate 
on the 172.31.x.x. / 255.255.0.0 network.

 

 
 

 

You will have to setup your computer IP address to match that network. We highly recommended using 172.31.3.150 as a fixed IP address 
for the computer with a subnet mask of 255.255.0.0.

 

 

 
Open the "Network Connections" control panel of 
your computer to adjust the IP address: 
 

 

Press  [Windows]  +  [R]  to  bring  up  the  Run 
Dialog box 

 

Type 

“ncpa.cpl” and press [Enter]

 

 

 
 
 

 

Double  click  on  the  Network  Adapter 
connected  to  the  DFF-

3D  (usually  “Local  Area 

Connection”).

 

 
 
 

 

 

Select  "Properties"  on  the  "Local  Area 
Connection Status" window.  

 

 

 

Note: If you have multiple Area Connections 

(multiple Ethernet Cards) and if you don’t know which one is connected 

to the DFF-3D, you can temporary disconnect the Ethernet Cable connected to the DFF-3D from the computer and 
look at which icon will display a red cross. This will indicate the LAN that has been disconnected from the computer, 
and the one that needs to be configured.   
 
 
 
 

 

Summary of Contents for DFF3D

Page 1: ...ddress for the computer with a subnet mask of 255 255 0 0 Open the Network Connections control panel of your computer to adjust the IP address Press Windows R to bring up the Run Dialog box Type ncpa...

Page 2: ...xed IP address mode Open the DFF 3D cover and make sure that all the S2 and S3 DIP Switches are set to the OFF position Connect the DFF 3D to the computer directly or better via a HUB Switch Note You...

Page 3: ...if the DFF 3D transducer has been installed the wrong way reversed Enter the distance on the bow stern axis in between the transducer and the ship s center of gravity in the Transducer Position Bow S...

Page 4: ...to SC30 location using the same rules as the Transducer to GPS location If your SC30 is also your primary GPS sensor you can enter the same offset as GPS location IMPORTANT For the best motion compens...

Page 5: ...ith a repeat interval of 10Hz minimum When using a PG700 or third party Heading Sensor 290ms if the Heading Sensor is connected via NMEA2000 using the Actisense NGT1 USB to NMEA2000 adapter 320ms if t...

Page 6: ...nal via the Ethernet connection on the NavNet NMEA port Also if the DFF 3D is directly integrated to the PC without any Furuno MFD on the network such as NavNet TZT or NavNet TZT2 TIMEZERO must be set...

Page 7: ...IMPORTANT In order for the boat icon to scale properly make sure to enter the Boat Length Boat Width and GPS location from the Initial Setup Options Note that the coordinate system used by TIMEZERO is...