background image

3

4

Important Installation Instructions

IF IN DOUBT CONSULT AN 

ELECTRICIAN.
Switch off mains electricity

Remove the existing light switch and transfer 

the wires to the security switch according to  

the following instructions. 
If the switch is an ON/OFF two wire type, 

those wires should be inserted into the 

terminals marked L1 and COM. Do not disturb 

any earthing wire connected to the wallbox terminal. If the switch is a 2-WAY 

switch, used in conjunction with a second light switch, it will have 3 wires.  

In this case the wire originally connected to the COM terminal must be inserted 

into the COM terminal, the remaining two wires connect to terminals L1 and L2  

in either position.  

If two wires are connected to any one terminal on the original switch, these should  

be kept together and inserted into the corresponding single terminal on the Digital 

Security Switch. Ensure that the terminal screws are tight before refitting the unit 

to the wall box and turning on the mains electricity. Lower the hinged cover, move 

the slide switch to the MANUAL position and check that the rocker switch operates 

the lamp normally. The unit terminals are suitable for 1mm

2

 and 1.5mm

2

 solid 

conductors and stranded equivalents. 

Note: The unit will replace any conventional single or  

two way switch.  

It cannot be used as an intermediate switch and cannot be used  

in conjunction with a lamp dimmer in 2 way switching.

Summary of Contents for ZV700

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 7 Day Digital Lightswitch with Optional Dusk Start Cat No ZV700...

Page 2: ...timed control of lighting on a weekly basis available at the slide of a switch There is a further option of starting an automatic lighting period at dusk but ending it in the usual way with a timed O...

Page 3: ...mme memory and the second is the ability to switch low energy fluorescent and low voltage lighting Override button also used in conjunction with the programme button to set the clock and ON OFF times...

Page 4: ...rminal the remaining two wires connect to terminals L1 and L2 in either position If two wires are connected to any one terminal on the original switch these should be kept together and inserted into t...

Page 5: ...Reset button with a pen or matchstick until the display disappears and then clears to show 0 00 system reset If the rocker switch is turned to the ON position and the Change button is pressed the ON s...

Page 6: ...iod has started but not to turn it ON during a programmed OFF period Override button also used in conjunction with programme button to set the clock and ON OFF times days Day marker 24 hour display Gu...

Page 7: ...utes are flashing they may be set using the Change button Once set the Program button is pressed again to proceed to the next stage Programming can be carried out with the slide switch in any position...

Page 8: ...y ii Hour Setting Press the Program button briefly to select the hours display shows clock symbol and the hours digits flashing Press the Change button to advance the hour setting For rapid hours sele...

Page 9: ...weekdays If another option is required the change button should be pressed until the correct day s flash ii Once the day option has been selected press Program button briefly to select hour time disp...

Page 10: ...ating Programme Mode This is required when making changes to the clock time day or programme times days and can be initiated any time during the normal operating mode Press the Program button briefly...

Page 11: ...dswhilstinnormaloperatingmodeasmall Rappearsonthedisplay TheunitwillnowswitchONandOFFinarandomfashionduring programmedONperiodsinbothAUTOandAUTO PHOTOCELLmodes BoththeONandtheOFF periodswillvaryinaran...

Page 12: ...e timeguard com HELPLINE 020 8450 0515 For assistance with the product please contact 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture wi...