11
8. Secure the back box to the wall using suitable screws for the rawl
plugs installed. Ensure that the back box is correctly orientated
following the ‘TOP’ marking which is labelled inside.
9. Pass though the 230V AC 50Hz mains supply cable and secure
the cables tightly to their respective terminals ensuring that all
bare conductors are sleeved and that correct polarity is observed,
see figure 9 and 10 for the appropriate wiring diagram for your
chosen product. Note that if metal conduit is being used the earth
continuity between the conduits must be maintained.
10. Once the mains supply is connected to the correct terminals,
mount the face plate over the back box aligning the four screws
from the face plate to the four mounting holes on the back box.
Tighten until secured.
Live Supply
to Load
230V 50Hz AC Mains Supply
Mains Neutral Supply
Neutral Supply to Load
Earth
5.1 WXT104NP, WXT204NP, WXT205NP Wiring Diagrams
Figure 9
WXT104NP