background image

N

COM

NC

NO

N

L

L

Fig. 7

Receiver Wiring Diagram

This unit is double insulated, and hence does 
not need connection to the earth. If earth 
continuity is required, please use the earth 
terminal on the wall plate, (see Fig. 4).

To reinstall the unit on the wall plate first ensure 
the wall plate retaining screws are loosened 
enough to clear the TRT037 receiver body then 
engage the top of the TRT037 receiver onto the 
wall plate retaining tabs (see Fig. 4), and push 
firmly downwards and then inwards. There will 
be some resistance from the terminals. Once in 
place, secure with the retaining screws.

Finally check that the system wiring is complete 
and correct.

4. Operation

Initially it is important to get the two parts 
(transmitter and receiver) talking to each other. 
This is best carried out by two people, one at each 
of the separate locations.

Press reset on the transmitter and at the receiver 
connect the mains supply to the unit. Both indicator 
lights (learn/manual and output on the receiver) will 
come on for around 3 seconds and then go out. Press 
and hold the learn button on the receiver for around 
10 seconds until the blue learn/manual light starts 
flashing.

At the transmitter press and hold the select and      
buttons until the flashing blue learn/manual light on 
the receiver goes out. The transmitter and receiver 
are now communicating. This can be confirmed by 
carrying out the following:- at the transmitter press 
the + button until the set temperature (identified by 
momentarily pressing the + or - button) is higher 
than the room temperature (normally displayed). 
After a short delay the output on light on the 
receiver comes on.

Now press the - button at the transmitter until the 
set temperature is lower than the room temperature 
and after a short delay the output light will turn off. 
This proves the communication is fully functional.

There is a manual facility available at the receiver. 
If the auto/manual (A/M) button is pressed the blue 

learn/manual light will come on indicating the receiv-
er is in manual mode. The receiver output can now 
be turned on and off using the learn button.

Programming

Decide whether weekday/weekend (5-2) or individual 
(7) day programming is required and move the 
appropriate jumper on the rear of the TRT037 
transmitter.

The temperature span (difference between on and 
off temperatures) can be adjusted between 1ºC and 
0.5ºC using a jumper found on the rear of the unit.

Optimum start (switching on earlier on colder 
mornings) can also be turned on or off using a 
jumper on the rear of the unit.

It is important to make these decisions first, 
as after any change of jumper position, reset needs 
to be pressed, which will return the unit to default 
time and programme.

Pressing any button illuminates the screen 
automatically.

During time/date and programme setting if a button 
is not pressed within 15 seconds the display will 
revert to the start of the sequence.

Setting date and time of day

Open programme access flap and press reset, using a 
pen or similar object. All of the screen segments will 
show briefly, and then the current room temperature 
will be displayed.

To programme the date and time of day, open 
programme access flap, and simultaneously press 
and hold both the select and set buttons for 3 
seconds. The year will flash.

Use the + and - button to set the correct year. 
Press select to move on to programming the month 
(shown to the left), and then again to programme 
the day. Press select again to 
programme the hours (am/pm), and again to 
programme the minutes (each time using the 
+/- button to make the change). Press set to return 
to operating mode.

If at any time a button is not pressed for 15 
seconds, the unit will return to operating mode.

Programming temperature periods for 
7 days option

Notes

1) There are no off periods with this controller. 

The programming sequence is:-

    Start time, temperature, second start time, 

second temperature and so on. Setting 
temperature to 10ºC is as close to off as can be 
achieved (and for most situations will be off 
unless the weather is very cold).

2) If you do not want a higher temperature period 

in the middle of the day adjust the temperature 
for this period downward to match those of the 
proceeding and subsequent period temperatures. 