background image

5

. Press ‘SET’ key once the 

 symbol flashes then press ‘+’ or ‘

’ keys to set ‘Comfort’ 

temp from 10

°

C up to 30

°

C  

6

. Press the ”SET” button and the 

 symbol flashes and set the ‘Set Back’ temp in the same 

way. 

7

. Once again press the ‘SET’ key and the 

 symbol is displayed. 

8

. Press ‘+’ or ‘

’ keys to set the floor limiter temperature from 20

°

C up to 30

°

C. 

(The floor limiter should not be set higher than 30

°

C.) 

9

. Press ‘SET’ key to exit. The control will then display the room temperature. 

 
The control will revert to

 

normal display after about 15 seconds, so if it goes back to showing 

time whilst you are setting it up just start again by pressing the “PROG” button and if you 
have already programmed the time simply press the “SET” button to skip to the next function 
to be set. This also applies if you just wish to change one function i.e. if you wish to change 
the “Comfort” temperature press “PROG” button and then “SET” button twice.  
 
 

Bathrooms 

This control should not be sited in a bathroom, so when using the control to regulate a 
heating mat situated in a bathroom it should be positioned outside the bathroom (not in an 
airing cupboard). The programs should be set as above to your own requirements but the 
temperatures should be set as follows - 
 

 

Comfort temperature at about 25

ο

C (in excess of the ambient temperature 

where the control is sited). 
 

             Set back temperature at about 16

ο

C.  

 

            The maximum floor temperature, use this to control the temperature of the 

bathroom floor, suggest trying 24

ο

C and then altering until you are satisfied with the floor 

temperature.   

 
 
 
 

Manual Temperature Setting  

 

A. Temporary Temperature Override. 

 

1

. Press ‘+’ or ‘

’. The 

indicator and the temperature will flash. 

2

. Press the ‘+’ or ‘

’ key to the desired temperature. 

3

. Press the ‘Set’ key once to confirm. The

 will flash every 3 seconds. It will stay in the 

temporary setting until the mode next switches from comfort to setback or vice versa. 

4

. To exit the temporary setting at any time, just press ‘SET’. 

 
 

Reviews: