6. Connection Diagram 

•  Connect the 230V 50Hz mains supply and load cables  

into the terminal block as follows;

230V 50Hz Mains Supply 

Live Supply (Brown or Red) to 

L

Neutral Supply (Blue or Black) to 

N

Load (Light Source) 

Switch Live (Brown or Red) to 

L

Neutral Load (Blue or Black) to 

N

Summary of Contents for Sure Time STW360

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 360 Surface Mount PIR Sensor Model STW360...

Page 2: ...ff and the circuit supply fuses are removed or the circuit breaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this PIR sensor and install in...

Page 3: ...onds to 18 minutes Dusk Level Adjustment 10 to 1000 Lux day and night or night time only operation Manual Override 6 hours max Warm up Time 60 seconds Operating Temperature 20 C to 40 C IP40 Rated sui...

Page 4: ...formance see image A and B detailing detection range and direction The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS See image B Therefore position...

Page 5: ...the top cover fully anti clockwise to release The top cover can now be removed from the sensor body Mark the position of the mounting holes using the sensor body as a template Drill out the mounting...

Page 6: ...sert mounting screws through the sensor assembly into the wall plugs and secure Do not overtighten if using a power screwdriver please ensure it is set to a low torque setting so as not to damage the...

Page 7: ...V 50Hz mains supply and load cables into the terminal block as follows 230V 50Hz Mains Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N Load Light Source Switch Live Brown or Red...

Page 8: ...warm up period The unit will now operate during daytime as well as at night illuminating the lamp for approx 3 seconds each time This allows testing to be carried out to establish whether the sensor...

Page 9: ...lamp illuminates 3 Leave the control knob set at this point At this position the unit should become operative at approximately the same level of darkness each evening Observe the operation of the uni...

Page 10: ...tes check for false activation from heat wind or a reflective source Check that the power is switched ON at the power supply or isolation switch Turn OFF the power to the unit and check the wiring con...

Page 11: ...h proof of purchase and it will be replaced free of charge For the second year or any difficulty in the first telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases...

Page 12: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppor...

Reviews: