7
8. Setting Up for Automatic Operation
(Auto Mode)
• When the walk tests are complete, the unit can be adjusted for
automatic operation.
• The Time Setting controls how long the unit remains illuminated
following activation and after all motion ceases.
• The minimum time (fully anticlockwise) is approx. 3 seconds, whilst
the maximum time (fully clockwise) is approx. 18 minutes. Set the control
to the desired setting between these limits.
• The Lux-Dusk/Dawn Setting determines the level of darkness required
for the unit to start operating. The setting is best achieved through
the procedure below;
1. Set the Lux-Dusk/Dawn Setting control knob fully anticlockwise.
2. When the ambient light level reaches the level of darkness at which
you wish the lamp to become operative (i.e. at dusk) SLOWLY rotate
the control in a clockwise direction until a point is reached where the
lamp illuminates.
3. Leave the control set at this point.
• At this position the unit should become operational at approximately
the same level of darkness each evening.
• Observe the operation of the unit. If the unit is starting to operate too
early (i.e. when it is quite light) adjust the control slightly anticlockwise.
If the unit starts to operate too late (i.e. when it is very dark) adjust the
control slightly clockwise.
• Continue to adjust until the unit operates as desired.
9. Manual Override Mode
The light can be switched ON for longer time periods through use of the Manual
Override Mode. This can be activated at night by using the isolation switch.
• Activate the isolation switch once (OFF/ON) within 1.5 seconds.
• The unit will now illuminate continuously for 6 hours or until it is
switched back to Auto Mode.
• To return to Auto Mode turn the isolation switch OFF and then back ON
again within 1.5 seconds.