background image

current room temperature 5 seconds after the last 

button press. The illumination will also turn off 
after 5 seconds. In manual mode, there will be a 
hand symbol displayed on the screen. The new 

temperature will remain valid until the next 

programmed period starts.
A burner symbol    is displayed when temperature 

is below desired value, indicating that the 
thermostat is calling for heat from the boiler.
Review set temperature
The set temperature can be reviewed at any time, 
by a single press of the + or - button. 5 seconds after 
this single button push, the unit will show the 
current room temperature, and the screen 

illumination will turn off.
Frost protection
Frost protection reduces the set temperature to 5ºC. 
Frost protection is activated by holding down the 
frost protection button for 3 seconds. When in frost 
mode, the frost symbol    will flash on the display. 
The set temperature buttons remain non-functional 
during frost mode. The unit will remain in frost 
mode until the frost button is held down for a 
further 3 seconds.
Battery replacement
When the battery needs replacing, a battery symbol 

    will flash on the display.

Sleep mode
The unit can be put into sleep mode by simultaneously 

holding down the + and - buttons for 3 seconds. 
Pressing any button will exit sleep mode. In sleep 

mode, all outputs are suspended and the screen is 

blank (useful for longer periods when the house 
is unoccupied and frost protection is not required).
To clean use a dry cloth only. Do not use any 

liquid cleaners.

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020-8452-1112

or email [email protected]

 Group company

67-058-328 (Iss.2)

HELPLINE

020-8450-0515

or email [email protected]

For assistance with the product please contact:-

3 Year Guarantee

In the unlikely event of this product failing due to defective material or 

manufacture within 3 years of the first date of purchase, please return it 

to your supplier in the first year for replacement free of charge. 

For years 2 and 3 or difficulty in the first year, please telephone the 

helpline 

020 8450 0515.

 Note: a proof of purchase is required 

in all cases. For all eligible replacements (where agreed by 

Timeguard Ltd) the customer is responsible for all shipping/postage 

charges for sending replacements outside the UK. All shipping costs 

are to be paid in advance before a replacement is sent. 

Wireless 7 Day 

Programmable 

Room Thermostat

Cat. No. TRT037

Operating & Installation Instructions

Receiver

Transmitter

Fig. 7

Receiver Wiring Diagram

This unit is double insulated, and hence 
does not need connection to the earth. 
If earth continuity is required, please use the 
earth terminal on the wall plate, (see Fig. 4).

To reinstall the unit on the wall plate first ensure 
the wall plate retaining screws are loosened 
enough to clear the TRT037 receiver body then 
engage the top of the TRT037 receiver onto the 
wall plate retaining tabs (see Fig. 4), and push 
firmly downwards and then inwards. There will 
be some resistance from the terminals. Once in 
place, secure with the retaining screws.

Finally check that the system wiring is complete 
and correct.

4. Operation

Initially it is important to get the two parts 

(transmitter and receiver) talking to each other. 
This is best carried out by two people, one at each 
of the separate locations.
Press reset on the transmitter and at the receiver connect 

the mains supply to the unit. Both indicator lights (learn/
manual and output on the receiver) will come on for 

around 3 seconds and then go out. Press and hold the 
learn button on the receiver for around 10 seconds until 

the blue learn/manual light starts flashing.
At the transmitter press and hold the select button for 
1 second, keeping it held down, press and hold the 

‘  ’ button so they are both held down together. 
Hold them both down until the flashing blue learn/
manual light on the receiver goes out. The transmitter 
and receiver are now communicating. This can be 
confirmed by carrying out the following:- at the 
transmitter press the + button until the set 
temperature (identified by momentarily pressing the 
+ or - button) is higher than the room temperature 
(normally displayed). After a short delay the output 
on light on the receiver comes on.
Now press the - button at the transmitter until the 
set temperature is lower than the room temperature 
and after a short delay the output light will turn off. 
This proves the communication is fully functional.
There is a manual facility available at the receiver. 

5. Specifications

Current rating:  3 (1) A
Voltage: 

230V, 50Hz

Switch type: 

Single pole, change-over (SPCO)

 

Volt Free Contact

Operating 
temperature 
range: 

0ºC to 50ºC

Set temperature 
range:  

10ºC to 35ºC adjustable in 

 

0.5ºC steps

Complies with: 

BS EN 60730

Span: 

1ºC or 0.5ºC

Micro 
disconnection: 

Type 1.B control action

Batteries: 

2 x AA alkaline

If the auto/manual (A/M) button is pressed the blue 

learn/manual light will come on indicating the 

receiver is in manual mode. The receiver output can 

now be turned on and off using the learn button.
Programming
Decide whether weekday/weekend (5–2) or 

individual (7) day programming is required and 

move the appropriate jumper on the rear of 

the TRT037 transmitter.
The temperature span (difference between on and 

off temperatures) can be adjusted between 1ºC and 

0.5ºC using a jumper found on the rear of the unit.
Optimum start (switching on earlier on colder 

mornings) can also be turned on or off using a 

jumper on the rear of the unit.
It is important to make these decisions first, 

as after any change of jumper position, reset needs 

to be pressed, which will return the unit to default 

time and programme.
Pressing any button illuminates the screen automatically.
During time/date and programme setting if a button 

is not pressed within 15 seconds the display will 

revert to the start of the sequence.
Setting date and time of day
Open programme access flap and press reset, using a 

pen or similar object. All of the screen segments will 

show briefly, and then the current room temperature 
will be displayed.

To programme the date and time of day, open 

programme access flap, and simultaneously press 

and hold both the select and set buttons for 

3 seconds. The year will flash.
Use the + and - button to set the correct year. 

Press select to move on to programming the month 

(shown to the left), and then again to programme 

the day. Press select again to programme the hours 

(am/pm), and again to programme the minutes 

(each time using the +/- button to make the 

change). Press set to return to operating mode.
If at any time a button is not pressed for 15 

seconds, the unit will return to operating mode.

Programming temperature periods for 
7 days option
Notes
1) There are no off periods with this controller. 

The programming sequence is:-

   Start time, temperature, second start time, 

second temperature and so on. 

  Setting temperature to 10ºC is as close to off 

as can be achieved (and for most situations 
will be off unless the weather is very cold).

2) If you do not want a higher temperature period 

in the middle of the day adjust the temperature 
for this period downward to match those of the 
proceeding and subsequent period temperatures. 

3) The TRT037 comes with a factory installed 

(default) programme for both 5–2 and 7 day 
options which you use or modify as you wish. 

Just pressing the reset button brings this 
programme into operation.

The default programme for every day is 

as follows:-
6:00 AM  

21ºC

8:00 AM  

17ºC 

 

12:00 PM 

21ºC

2:00 PM  

17ºC 

4:00 PM  

21ºC

10:00 PM 

17ºC

For both 5–2 and 7 day options.
To programme the temperature periods, press 
the set button. Mon will flash. To programme 

Mondays time/temperature periods press select 
button. Alternatively use the + and - buttons to 
change the day, and then select to continue. The 
time will then flash. This is the start time for the first 
period. Press + or - to set the hour for the start time 
for period 1. Press select to move to the minutes. 

Use the + and - to set the minutes. Press select to set 
the temperature for this period. Use the + or - keys 
to set the desired temperature. Press select again 
to programme the next time period. There are 
6 time periods per day. 

Once the 6 periods for Monday are programmed, 

Press set button, and Monday will start to flash. 
Use the + and - button to change the day to Tuesday, 
and then use select to program Tuesdays time 

periods and temperatures. For 7 day programming, 
this will need to be done for all 7 days. If set is pressed 
twice, the unit will return to operating mode.
Omitting Days
Omitting a day can be achieved by selecting 
10ºC for every time period for that day 

(all times and temperatures must be entered). 
The heating will not turn on unless the room 

temperature falls below 10ºC (50ºF).
Programming temperature periods for 
5–2 days option
For 5–2 day mode, time periods and temperatures 
will need to be programmed for M–F and then 
for S–S. i.e.: only 2 sets of times need to be 
programmed, not 7 (individual) sets of times.
Temperature override
In operating mode, the temperature set for the 
current period can be overridden. To adjust the set 
temperature, press the + or - button once. The screen 
will illuminate blue while button is pressed. 
Use + and - buttons to set desired temperature. 
If the + or - button is held down, the display will 
advance rapidly. Once the desired temperature 
is set, the unit should revert to displaying the 

N

COM

NC NO

N

L

L

Connections to boiler

Check boiler instructions 

before connecting

Reviews: