background image

LEDX10PIRB.1 & LEDX20PIRB.1 Instructs_147x105-R2a   1-6

17-01 -14   9.37AM

Prepared by Sally

1

2

3

4

5

6

  (FRONT)

1. Designated Use

•  LEDX10PIR and LEDX20PIR are an outdoor motion detector for
   automatic LED lighting control.
•  Mainly for wall installation.
•  Simple plug in wall plate for easy & safe connection
•  Suitable for a wide range of locations: corridors, gardens, staircases, 
  entrances, garages, outdoor parking areas etc.

Index :

Page 2 

Contents and Tools required

Page 3 

Connection and Installation procedure

Page 4 

Installation procedure

Page 5 

Sensor detection range

Page 6 

Walk test & adjustment, Detector head adjustment

Page 7 
Page 8 

Lens masking

Page 9 

Manual Override Mode, Lamp adjustment and Warning

2. Basic Safety Instruction

Danger of death through electric shock.
•  Must only be installed by qualifi ed electricians.
•  Avoid the metal parts of the device due to potentially high temperature.

•  Designed for use in normal environments
•  Intended for outdoor installation.
•  Energy saving.
•  Long LED lamp life time.

Page 10   Technical specifications

18

0

1.

TO

 2.

ME

TE

R

12 ME

TER

3 METER

18

0

1.8 

TO

 2.5 

M

E

TER

12 ME

TER

3 METER

18

0

1.

TO

 2

.5 M

E

TE

R

12 ME

TER

3 METER

10

20

30

40

40

10

20

30

40

40

Detection Range:

LEDX10PIR and LEDX20PIR:

Recommended installation height is 2.5 meter above

ground, the maximum detection range about 12 meter and at the angle 

of about 180 deg.

180°

up to12m

3m

18

0

2.5 M

E

TE

R

12 ME

TER

3 METER

180°

10

20

30

40

40

Setting advise and Knob settings

 

•  Switch power on.

The detector head can be 90º turned left or right by hand and can be tilted 
90º downward .

Detector Head Adjustment

Walk Test and Adjustment

The purpose of Walk Test is used to test and adjust the detection coverage of 

LEDX10PIR and LEDX20PIR under auto mode.

•  Adjust the Time knob to minimum (fully anti-clockwise), then conduct a 

   walk test as described in test procedure. 

Test procedure:

•  Adjust the Time knob to  (fully anti-clockwise), (Lux knob can be “Sun” or

   Moon”).

•  Walk across the detection area, once the detector is triggered the lamp 
  will turn ON for 2 seconds.

Note walking direction when performing test.

* Do not use the adjuster knobs to turn 

the detector head.

0

2

Sec

2 sec

Dusk

Time

Test mode

Tilt down 90º

Pan left 90º

Pan right 90º

Installation Advise:

WARNING

WARNING

As the detector reacts to variations in temperature, avoid situations:

• Do not install motion detectors near heat sources such as heating outlets,

  air conditioning system, lamps etc.
• Do not direct the motion detector at objects that move in the wind such 

   as curtains, large plants etc. 
• Take account of motion direction during test run.

• Do not direct motion detectors at objects with highly-reflective surface 

   such as mirrors etc.

3. Contents:

   What’s in the box?

4. Tools required:

Tools / Equipment need for installation. 

INSTRUCTIONS

MANUAL

X 1

X 1

X 1

X 2

X 2

X 1

Screw: 

M4x32mm   

Screw peg:

 6x30mm

X 1

X 2

Screw: M3x12mm   

X 1

X 1

X 1

Flat blade screw driver

Suitable for screw head

Drill bit with diameter 6mm

5

Connect device

to the mains.

Unit goes into 

warm-up period 

for 40 sec.

Connect the mains supply 

cable to the on the terminal 

block backplate as follows.

( See connection diagram )

CONNECTION

10

Loosen the screws.

Attach the 

wallplate 

to the device.

12

8

Connect the individual wires to the appropriate terminal then tighten

the screw.

First, feed the cable through the 

rubber gasket of the junction box.

“Click”

Push

9

11

Attach the strain relief to the 

device and screw in.

Tighten the screws.

6

7

EARTH

Attach the device to the U 

bracket then tighten the 

screws on both sides.

LIVE

NEUTRAL

EARTH

BLUE

GREEN / YELLOW

BROWN

•  Conforms to the latest EC directives. 
 

Connect the cable to the terminal block as follows 

(see connection diagram):

Ensure the connections are secure. Refit wall plate ensuring it clicks

firmly into place.

5. Connection:

Switch off the electricity at the fuse box by removing the relevant fuse or 

switching off the circuit breaker before proceeding with the installation.

*** IMPORTANT ***

2

3

1

230V

4

Mounting  Srews: (M4 x 32mm) x 2

φ 6mm

Fix the U bracket to the wall.

Switch off the power.

Drill and push the screw 

peg into the hole.

Marking the screw hole.

6. Installation Procedure:

  Srews: (M3 x 12mm) x 2

LIVE

NEUTRAL

EARTH

BLUE

GREEN / YELLOW

BROWN

Mains

Supply

 Isolation  Switch

N
L

E

Product’s weight
LEDX10PIR: 0.55kg, LEDX20PIR: 0.72kg

Max wire

1 x 2.5mm per way

Summary of Contents for LEDX10PIRB

Page 1: ...LED PIR FLOODLIGHT Model LEDX10PIRB Model LEDX10PIRWH Model LEDX20PIRB Model LEDX20PIRWH...

Page 2: ...stallation procedure Page 5 Sensor detection range Page 6 Walk test adjustment Detector head adjustment Page 7 Page 8 Lens masking Page 9 Manual Override Mode Lamp adjustment and Warning 2 Basic Safet...

Page 3: ...ipment need for installation INSTRUCTIONS MANUAL X1 X1 X1 X2 X2 X1 Screw M4x32mm Screw peg 6x30mm X1 X2 Screw M3x12mm X 1 X 1 X 1 Flat blade screw driver Suitable for screw head Drill bit with diamete...

Page 4: ...box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation IMPORTANT 2 3 1 230V 4 Mounting Srews M4 x 32mm x 2 6mm Fix the U bracket to the wall Sw...

Page 5: ...h the wallplate to the device 12 8 Connect the individual wires to the appropriate terminal then tighten the screw First feed the cable through the rubber gasket of the junction box Click Push 9 11 At...

Page 6: ...t 180 deg 180 up to12m 3m 1 80 2 5 METER 1 2 M E T E R 3 METER 180 10 20 30 40 40 Installation Advise WARNING As the detector reacts to variations in temperature avoid situations Do not install motion...

Page 7: ...de Adjust the Time knob to minimum fully anti clockwise then conduct a walk test as described in test procedure Test procedure Adjust the Time knob to fully anti clockwise Lux knob can be Sun or Moon...

Page 8: ...t the knob as desired LUX knob setting When setting the Lux knob at MOON LEDX10PIR or LEDX20PIR will only operate in the dark When setting the Lux knob at SUN LEDX10PIR or LEDX20PIR will operate in an...

Page 9: ...ens Lens masking Setting Advise WARNING To restrict the sensor coverage preventing detection in unwanted areas mask the sensor lens using the masking label provided The top section of the lens covers...

Page 10: ...ntinuously until dawn or until switched back into Auto Mode To switch the unit back into Auto Mode switch the internal wall switch circuit breaker once OFF ON within 1 5 second The unit will return to...

Page 11: ...oubleshooting Guide If problems still exist do not immediately return the unit to store Telephone the Timeguard Customer Helpline Qualified Customer Support Co ordinators will be on line to assist in...

Page 12: ...s 4 Timeguard Limited Victory Park 400 Edgware Road London NW2 6ND Sales Of ce 020 8452 1112 or email csc timeguard com For a product brochure please contact or email helpline timeguard com HELPLINE 0...

Reviews: