5

6

6.1 Setting the Clock

NOTE: Pauses of 15 seconds or more 
during programming will result  
in automatic return to the main  
operating screen.

1.  To prepare the module for programming  

clear the memory by pressing both the  
Set and Day buttons simultaneously until  
the display disappears. On releasing the 
buttons the display will show 0:00 INT  
with the colon flashing.

2.  To set the current time press the Set button 

briefly and release, the display shows 

0:00 

INT

 

with “C” flashing at the right of the display. 

3.  Press the Day button until the black dot 

indicates the current day of the week (1–7).  
1 = Monday, 2 = Tuesday, and so on.

4.  Use the Hrs button to set the hours followed 

by the Mins button to set the minutes to the 
current time of day. Rapid selection can be 
achieved by continuously holding down either 
the Hrs or Mins buttons.

5.  If the Set button is now pressed briefly and 

then released, the display will return to the 
current time of day with the colon flashing. 
The module is now displaying the main 
operating screen.

Summary of Contents for EMU56

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 24 Hour 7 Day Electronic OEM Time Control Module Model EMU56...

Page 2: ...e and install in accordance with the current IEE wiring and Building Regulations Check that the total load on the circuit before attempting to use the time module for your OEM application 3 Technical...

Page 3: ...gned for use with the PB04 power board which is operated from 220 240V AC mains provides a relay output with voltage free normally open contacts which can carry up to 10A resistive or 6A inductive and...

Page 4: ...3 4 5 Connecting Diagram Diagram 1...

Page 5: ...tons are used to set the days hours and minutes as required Please see diagram 2 for reference Setting buttons for days hours and minutes Output status showing either ON or INT OFF 24 hour digital dis...

Page 6: ...tton briefly and release the display shows 0 00 INT with C flashing at the right of the display 3 Press the Day button until the black dot indicates the current day of the week 1 7 1 Monday 2 Tuesday...

Page 7: ...me 1 2 Appearing underneath the ON indicator and the day indicator will point to day 1 To programme the first ON OFF times for day 1 set the ON time required by pressing the Hrs and Mins buttons separ...

Page 8: ...amming will result in automatic return to the main operating screen 1 If the display still shows a day 1 ON or OFF programme press the Day button and the day indicator will move above day 2 2 If inste...

Page 9: ...ogrammes NOTE Pauses of 15 seconds or more during programming will result in automatic return to the main operating screen 1 Press and hold down the Set button for about 3 seconds until the first ON p...

Page 10: ...g the Programmes NOTE Pauses of 15 seconds or more during programming will result in automatic return to the main operating screen 1 Press and hold down the Set button for about 3 seconds until the fi...

Page 11: ...where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent out 4 To review anoth...

Page 12: ...r a product brochure please contact Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return the unit to the stor...

Reviews: