INST
ALLA
TION & OPERA
TING
INSTRUCTIONS
CEILING
DETECTOR/ALARM
WITH REMOTE
CONTROL
Cat No. TG123SK
TG123SK_Instructions.qxd 2/5/06 4:34 pm Page 12
Page 1: ...I N S TA L L AT I O N O P E R AT I N G I N S T R U C T I O N S CEILING DETECTOR ALARM WITH REMOTE CONTROL Cat No TG123SK TG123SK_Instructions qxd 2 5 06 4 34 pm Page 12 ...
Page 2: ...Please read the instructions before using the product and retain for future use 105dB alarm PIR detection lens Remote control LED Remote control unit Tough impact resistant case Low battery warning LED Infra Red Sensor Fig 1 TG123SK_Instructions qxd 2 5 06 4 34 pm Page 1 ...
Page 3: ...g a key fob remote control Entry and exit delays along with low battery voltage warning are built into the unit The unit also has a panic facility available in the disarmed state where the alarm can be immediately started for a 30 second period by pressing the PANIC button on the remote This can be ended before the 30 seconds are up by pressing the DISARM button TG123SK_Instructions qxd 2 5 06 4 3...
Page 4: ...all the battery in the compartment and feed the lugs on the cover into their respective slots on the case Push downward on the cover near the catch until it snaps into place Remote Control Press down as shown in fig 3 then slide out If necessary remove the batteries from the compartment and insert 3 new SR44 silver oxide batteries with polarities as shown in fig 3 Engage the catch and the lugs on ...
Page 5: ...gs Battery compartment cover Case slides Catch Lug Battery compartment Battery compartment cover Press down here Slide out Fig 3 Fig 2 Main unit rear view Remote control rear view Catch TG123SK_Instructions qxd 2 5 06 4 34 pm Page 4 ...
Page 6: ...s at the position marked These should be positioned to ensure that the infra red sensor is pointing towards the main entrance door for ease of arming and disarming Fit the plugs if necessary and screws supplied leave the screw heads 3mm proud of the ceiling Offer up the main unit so that the screw heads fit into the large areas on the keyhole fixings then slide the unit sideways so that the screw ...
Page 7: ...use only Keep away from direct sunlight Loud alarm keep away from ears Do not locate near radiators or heaters Do not locate near fans Fixing Template Actual Size Fig 4 36 0mm 30 5mm TG123SK_Instructions qxd 2 5 06 4 34 pm Page 6 ...
Page 8: ...ote is pressed the LED on the remote flashes rapidly to show that it is operating correctly DISARM ARM PANIC DISARM button ARM button Red PANIC button Key chain Remote control LED Fig 5 7 TG123SK_Instructions qxd 2 5 06 4 34 pm Page 8 ...
Page 9: ...rther bleep to indicate the unit is active Entry Delay and Alarm Timing There is a 20 second delay after detection before the unit sounds the alarm allowing users to disarm the unit when returning after the 20 second delay the alarm sounds for 2 periods of 30 seconds separated by 30 seconds of silence Disarming Press the DISARM button on the remote control this also stops the TG123SK if it is alre...
Page 10: ...he LED flashing see fig 1 every 3 seconds This only occurs when the unit is armed Checking the System We suggest after installation that one or more trial runs are made after arming with the installer moving along routes that an intruder might take The unit being disarmed and re armed prior to the next route being taken after the 60 second exit and 20 second entry delays We suggest this procedure ...
Page 11: ... proof of purchase and it will be replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Specifications PIR detection 5 7m diameter circle at floor level Alarm 105dB Batteries PP3 Alkaline main unit 3 x SR44 or similar remote 357 SR44W RW42 SG13 SR1154 V303 A THREE YEAR GUARANTEE 3 10 TG123SK_Instructions qxd 2 5 06 4 34 p...
Page 12: ...PLINE 020 8450 0515 For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND 020 8452 1112 or email csc timeguard com TG123SK_Instructions qxd 2 5 06 4 34 pm Page 7 ...