Time Guard SLFM360 Installation & Operating Instructions Manual Download Page 12

HELPLINE

020-8450-0515

For a product brochure please contact:

Timeguard Ltd.

Victory Park, 400 Edgware Road,

London NW2 6ND

020-8452-1112

or email [email protected]

3 Year Guarantee

In the unlikely event of this product becoming faulty due to
defective material or manufacture within 3 years of the date 

of purchase, please return it to your supplier in the first year 
with proof of purchase and it will be replaced free of charge. 

For the second and third years or any difficulty in the first 

year telephone the helpline on 

020 8450 0515.

THREE YEAR

GUARANTEE

3

SLFM360_Instruct_art_2.2.qxd  3/5/06  10:05 am  Page 7

Summary of Contents for SLFM360

Page 1: ...I N S TA L L AT I O N O P E R AT I N G I N S T R U C T I O N S 360 FLUSH MOUNT CEILING PIR LIGHT CONTROLLER Cat No SLFM360...

Page 2: ...or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the fl...

Page 3: ...ewired to bridge across live supply from AC mains to the output load via the contacts In the above illustration the L1 L2 terminals are used to control a DC load or if the load uses a different phase...

Page 4: ...le for indoor use only Connected load must not exceed maximum 2000W filament incandescent or 500W fluorescent low energy lighting Do not attempt to install if you are suffering from nausea or dizzy sp...

Page 5: ...ation under extreme conditions During extreme weather conditions the motion sensor may exhibit unusual behaviour This does not indicate a fault with the sensor Once normal weather conditions return th...

Page 6: ...F Remove the factory fitted bridge wire Connect the 3 core mains supply cable to the terminal block on the unit as follows NEUTRAL Blue N EARTH Green Yellow LIVE Brown L Connect the load in series wit...

Page 7: ...e centre of the sensor location with a 2 5m ceiling As you cross a detection zone the lamp will illuminate Now stand still until the lamp extinguishes this should take approx 5 seconds Start moving ag...

Page 8: ...e DUSK control knob fully anti clockwise The unit will now start operating at dusk If you require the light to activate earlier wait until the ambient light level reaches the level of darkness at whic...

Page 9: ...t back into position under spring pressure Manual Override Mode The light can be switched on for longer time periods by use of the Manual Override Mode This can be activated at night by using the isol...

Page 10: ...has failed replace Ensure that the lamp is seated correctly in the lampholder Please note that the unit will not detect through glass e g in a glazed porch The level of ambient light in the area may b...

Page 11: ...t low energy lighting Not suitable for discharge lighting 75W Fan 5 seconds 18 minutes Day night or night only operation Internal use only 73 23 EEC and 89 336 EEC Technical specifications Detection R...

Page 12: ...In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier in the first year with proof of...