Time Guard NTT02 Installation & Operating Instruction Download Page 4

3

4. Programming the  

time switch:

a) Decide what times you would like the time switch 

to switch ON and Off.

b) Push the required segments down for the  

duration of an ON period, and pull them up for the 
duration of an Off period. The minimum switching 
interval is 15 minutes, and this can be increased  
in 15 minute steps.

c) Set the correct time, by rotating the dial clockwise 

until the correct time is indicated by the triangular 
pointer. Note that as the dial is rotated there will 
be an increased resistance to turning as ON/Off 
periods are passed.

Points to note:

The segment dial can be turned whilst the time 
controller is operating.
In case of power failure, re-adjust the time controller 
to the correct time of day by turning the dial in a 
clockwise direction until the correct time is indicated 
by the pointer.

for wiring, the terminals are marked as follows:

L

 

Live supply.

N

 

 Neutral supply.

S IN

  Live Input for volt free output  

(or a link can be added between  
L and S IN if volt free is not required).

S OUT

  Switch live output to heater or other appliance. 

Reviews: