Time Guard MLB98 Installation & Operating Instructions Manual Download Page 2

1

1. General information:

The unit utilises passive infrared technology to detect heat radiation of moving human bodies. 
Upon detection, the lamp will illuminate for a user-determined time period. 
An integral daylight sensor ensures night-only operation.

Parts Included

 

•  Luminaire c/w PIR Sensor unit.
•  Instruction manual. Please keep safe  
  for future reference.
•  20W Compact fluorescent lamp.
•  Accessory pack.

Unit is for outdoor use only. Unit must be mounted on a non-flammable surface as a fixed 
luminaire, and is not suitable for portable use.
The unit can get very hot during use. Ensure the unit has cooled before handling.
Ensure adequate ventilation space is allowed between the unit and any object above, in front 
or to either side of the unit. Suggested space is 0.5m above, 0.3m to either side & 1.0m in front.
If in any doubt, consult a qualified tradesperson or electrician.

2. Selecting the location:

The motion detector has a number of detection zones, at various vertical and horizontal angles 
as shown (see diagram A). 
A moving human body needs to cross/enter one of these zones to activate the sensor.  
The best all-round coverage is achieved with the unit mounted at the optimum height of 2.5m. 
Careful positioning of the sensor will be required to ensure optimum performance.  
See diagram A detailing detection range and direction.
The sensor is more sensitive to movement ACROSS its field of vision than to movement directly 
TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the 
likely approach path.
Avoid positioning the sensor where there are any sources of heat in the detection area  
(extractor fans, tumble dryer exhausts etc.). 
Reflective surfaces (i.e. pools of water or white-painted walls) and overhanging branches may 
cause false activation under extreme conditions.
During extreme weather conditions the motion sensor may exhibit unusual behaviour.  
This does not indicate a fault with the sensor. Once normal weather conditions return,  
the sensor will resume normal operation.

Tools & Parts Needed

 

•  Electric/hand-held drill & bits.
•  Terminal or Electricians screwdriver.
•  Large slotted/philips screwdriver.
•  Wire cutters.

Summary of Contents for MLB98

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 60W Multi PIR Bulkhead Model MLB98 Black...

Page 2: ...horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimu...

Page 3: ...he holes Pierce the grommet and pass the cable through the grommet Clamp the cable to the rear of the unit before securing the unit to the wall Fit grommet into its location hole ensuring a good seal...

Page 4: ...es from the unit Each time you are detected the lamp will illuminate Now stand still until the lamp extinguishes this should take approx 5 seconds Start moving again when you are detected again the la...

Page 5: ...e too early i e when it is quite light adjust the control slightly anti clockwise If the unit starts to operate too late i e when it is very dark Adjust the control slightly clockwise Continue to adju...

Page 6: ...me can be set by rotating the centre adjustment knob as required See diagram E the adjustment knob is identified by the letter T inside a circle This time adjustment is factory set to 1 hour Please no...

Page 7: ...th one second and the unit will return to Automatic Mode The light will illuminate only when motion is detected You may not be allowing the unit time to complete it s warm up period Stand well out of...

Page 8: ...If the PIR still activates the setting is still too high Repeat the above procedure until the PIR does not activate when you enter the detection area Refer to previous section for more details Unit ma...

Page 9: ...8 N L L1 Less sensitive More sensitive Top View 200 Side View 12m 2 5m A C B D Terminal cover...

Page 10: ...9 E Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Override Holiday Mode Time F...

Page 11: ...it will be replaced free of charge The lamp supplied is not included in the warranty For years 2 to 5 or any difficulty in the first year telephone our helpline on 020 8450 0515 Note A proof of purcha...

Page 12: ...400 Edgware Road London NW2 6ND Sales Office 020 8452 1112 or email csc timeguard com For a product brochure please contact For assistance with the product please contact Zerofour September 2014 or em...