Time Guard ECO18P Instructions Manual Download Page 6

SECTION THREE

OPERATION AND TESTING

SETTING UP FOR AUTOMATIC OPERATION

 

The adjustment controls on the unit (diagram F) should be set as follows.
The 

TIME

 control determines how long the lamp remains illuminated after activation. 

There are 5 designated “time on” settings O (or off), 2, 4, 6, 8 hours and dusk/dawn. 
These settings allow the lamp to illuminate for the designated time on period after darkness falls 
and the unit is activated.
If you require the lamp to be illuminated all night, set the time control fully clockwise to “Dusk/ 
Dawn”. The unit will then remain on until the following morning when the lux level increases 
enough to switch the unit off during the day.
The 

DUSK (LUX)

 control determines the level of darkness required for the unit to start 

operating. 
The setting is best achieved by the procedure below:

Set the DUSK control knob fully anti-clockwise

 and the Time control to the required 

number of hours or dusk/dawn (do 

not

 leave in the O (off, fully anti-clockwise) position).  

Wait until darkness falls. 
When the ambient light level reaches the level of darkness at which you wish the lamp to 
become operative (ie. At dusk), SLOWLY rotate the control in a clockwise direction until a point 
is reached where the lamp illuminates. Leave the control set at this point.
At this position, the unit should become operative at approximately the same level of darkness 
each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. 
when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too 
late (ie. only when it is very dark), adjust the control slightly clockwise.
Continue to adjust until the unit operates as desired.

MANUAL OVERRIDE MODE

The light can be switched on for longer time periods by use of the 

Manual Override Mode.

 

This can be activated at night by using the internal wall switch or circuit breaker supplying the 
unit.
please note:- The unit CAnnOT be operated in Manual Override Mode during daylight hours. If 
you want to test this function when installing the unit, this test must be carried out after dusk 
when the unit has become operational.

To activate Manual Override Mode:-

Switch the internal wall switch/circuit breaker once (off/on) within 1 second.
The unit will now illuminate continuously until dawn or until it is switched back into Auto Mode.

To de-activate Manual Override Mode (ie. switch the unit back into Auto Mode):-

Switch the internal wall switch/circuit breaker once (off/on) within one second. The unit will 
return to its Auto mode and will operate as set up initially.

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Summary of Contents for ECO18P

Page 1: ...i n s t r u c t i o n s 18W Nightsensor Bulkhead Cat No ECO18P Instructions Downloaded from Elcodis com electronic components distributor...

Page 2: ...Horizontal location Retaining clip Wall fixing hole Wall fixing hole Wall fixing hole Wall fixing hole Sensor Sensor B D A C Vertical location Horizontal location Downloaded from Elcodis com electroni...

Page 3: ...F E Cable clamp LUX Time OFF Downloaded from Elcodis com electronic components distributor...

Page 4: ...1 0mm or 1 5mm Electric hand held drill bits Terminal or Electricians screwdriver Wire cutters Do not attempt to install during wet weather if you are suffering from nausea or dizzy spells or onmedic...

Page 5: ...ter seal Fix the unit plate to the wall HORIZONTAL MOUNTING Diagram D Position the unit in the desired position based on the location of the incoming power cable Using the unit as a template mark the...

Page 6: ...he lamp illuminates Leave the control set at this point At this position the unit should become operative at approximately the same level of darkness each evening Observe the operation of the unit If...

Page 7: ...240V 18W 4pin GX2Dq 2 Low Energy lamp 2 4 6 8 hours from dusk or dusk dawn Day night or night only operation IP44 suitable for outdoor use Conforms to 73 23 EEC 89 336 EEC If you experience problems...

Page 8: ...brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND Tel 020 8452 1112 or email csc timeguard com A Group company For assistance with the product please contact 67 058 31...