3
Installation
IMPORTANT
Switch off the electricity at the fuse box by removing
the relevant fuse or switching off the circuit breaker
before proceeding with the installation.
Remove the wall plate from the floodlight by
unscrewing the fixing screw (Fig A). This screw is
captive. Do not remove completely from the floodlight.
Position the wallplate in the intended area and mark
position of the fixing holes. (Fig C)
Drill the holes. Insert the wall plugs into the holes.
PASS THE CABLE THROUGH THE WALL BRACKET
BEFORE SECURING WALL BRACKET TO THE WALL.
Pierce the grommet and pass the cable through the wall
bracket.
Allow approximately 100mm of cable to pass through
the grommet. (A template for this wire length is
provided on page 8 of this manual).
Fit grommet into its location hole ensuring a good seal.
Fix the mounting plate to the wall. Take care not to
overtighten the screws to prevent damage to the
mounting plate. If using a power screwdriver, use the
lowest torque setting.
Connection
This unit is supplied with a hanging attachment
(tether) to aid installation.
If it is not required, simply remove from the unit and
discard.
Place the round end of the tether into the keyhole
shape location hole on the wall bracket.
Ensure the tether is securely fixed into the slot before
releasing the weight of the unit.
The unit can now be suspended below the wall bracket.
(Fig B)
iTLRX150B_500B_Instructions.qxd 1/19/05 12:05 PM Page 4