© 2008 Timberline Tool All Rights Reserved.
OPERATING PROCEDURE
Remember this is only a recommended
procedure for a safe and effective
squeeze-off. Always follow your speci
fi
c
company safety rules when working
around natural gas.
1. Ground the tool with the
Grounding Rod
.
(Fig 1)
2. Rotate
the
Jaw Sleeve
so the cor-
rect pipe size lines up with the pipe size
indicator arrow shown on the
Tool Link.
(Fig 2)
3. Install the optional extension handles on the tool
and secure with the locking pin.
(Fig 3)
Make sure the pipe is clear of any
debris, rock, dirt, etc.
4. Disengage
the
Safety Locking Bar
and place
the
Quick Release Pin
in the hole through the
Top Handle labeled UNLOCK.
(Fig 4)
5. Open the tool and place over the pipe until the
Tool Links
are tight against the pipe.
(Fig 5)
6