9. TROUBLESHOOTING
In case of emergency, please, use the troubleshooting methods shown in
tables. If it is impossible to solve problems with these methods, apply to
the service center.
8. CLEANING AND MAINTENANCE
• Always unplug the unit before removing the water tank.
• Do not touch the water in the base during operation!
• Caution-risk of electric shock and damage of the product!
• Switch off the appliance and unplug it from the socket before cleaning it.
Clean the water tank and the base regularly. Use water only, no detergents.
IMPORTANT!
To avoid deformation or wear of working surfaces,
resulting in decreased atomizing or other malfunctions,
do not use metallic brushes, blades or talc powder
to wipe the atomizer’s surface. The water tank may
leak upon heavy impacts. In case of water leakage,
immediately stop using the unit and contact a service
center. To keep the unit dry, remove water after cleaning
and make sure to dry the unit’s case. Make sure that
there is no water left inside the unit’s case. Prior to a
long break in using the unit, dry its surface and pack it
into a plastic bag, then put it into a box. Store the unit in
a low-humidity room. Storing the unit undried results in
generation of mold
Problem
Possible cause
Remedy
Poor atomizing (insufficient
capacity)
The unit is operating in the minimized
mode (low atomizing frequency)
There is no problem. If you need to switch
to the intensive mode of operation, turn the
regulator handle all the way to the right.
The atomizer is clogged
Clean the atomizer.
Temperature of water in the tank is too low
Set maximum capacity. The humidifier’s
capacity will go up after a while.
No atomizing
The power cord is poorly connected
to the outlet
Connect the power cord into the outlet
carefully
There is white deposit on objects
around the humidifier (salts,
separating out from water)
1. Lime deposits have formed on the
membrane
2. There is a lot of salts in the water used
(calcium and magnesium)
1. Clean the humidifier’s membrane with a
special brush
2. Use filtered water
Steam has an unpleasant odor
Stale water is used
Clean the unit according to the cleaning
and servicing instructions and fill the tank
with fresh water
Remains of stale water or waste have
accumulated in the unit’s case or the
atomizer
Condensate is formed on the
upper part of the humidifier and
on surrounding objects, when it is
operating.
1. High humidification intensity is set.
2. High room humidity and temperature.
Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
Water appears next to the humidifier,
when it is operating.
1. High humidification intensity is set.
2. Lime deposits have formed on the
membrane and in grooves for water (in
the unit’s base).
1. Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
2. Clean the unit according to the cleaning
and servicing instructions.
Water appears next to the humidifier,
when it is not operating
Water tank is leaking
You need to contact an authorized service
center
for you on their own feelings, or use of this special instrument hygrometer
(sold separately), which measures the level of relative humidity.
Automatic shut-off in the absence of water.
By lowering the water level in the reservoir below the minimum ultrasonic
device will automatically turn off the membrane and on the control panel,
red LED lights.
To continue the operation of the device is necessary to fill the tank with
water according to the manual for its filling, and connect the device to the
mains.
Air flavoring
The device is equipped with an aroma capsule. When you add in her
aromatic oils occur fragrance. Aromatic oil supplied is not included.
Switching off
To turn off the unit, press the button on the control several times while
flashing blue activity light panel, and unplug the appliance.