www.timberk.com • электрический увлажнитель воздуха
7
1. When transporting, any possible impacts and movements of the
package inside a vehicle must be avoided.
2. Handling symbols on the unit’s package must be strictly observed when
transporting and storing it.
9. TRANSPORTATION AND STORAGE
In case of emergencies use troubleshooting methods, listed in Table 2, 3.
If it is impossible to remedy problems by the listed methods, contact the
manufacturer’s service center.
10. TROUBLESHOOTING
IMPORTANT!
To avoid deformation or wear of working surfaces,
resulting in decreased atomizing or other malfunctions,
do not use metallic brushes, blades or talc powder to
wipe the atomizer’s surface.
The water tank may leak upon heavy impacts.
In case of water leakage, immediately stop using the
unit and contact a service center.
To keep the unit dry, remove water after cleaning and
make sure to dry the unit’s case.
Make sure that there is no water left inside the unit’s
case.
Prior to a long break in using the unit, dry its surface
and pack it into a plastic bag, then put it into a box.
Store the unit in a low-humidity room.
Storing the unit undried results in generation of mold
Temperature
requirements*
Humidity
requirements*
We are researching new technologies and constantly improving the quality
of our products. Specifications, design and scope of delivery may be
changed without any prior notice.
* Products must be stored in dry, ventilated storages at the temperature not lower than -30°C
Transportation and
storage
-30°С to +50°С
15% to 85%
(no
condensate)
cools down, to avoid getting burned.
Use a damp and soft fabric to wipe the unit’s external surface.
To avoid electric shock do not scratch or damage elements of the unit
when cleaning.
When cleaning, do not use solvents, benzene, xylene, scrub brush, talc
powder and other substances except for water.
Wipe off remains of water inside the unit’s case using a damp and
soft fabric.
To wipe of remains of water on small parts you can use a soft brush and
then wipe them with a soft fabric again.
Clean the unit once or twice a week.
In case of dirt on the membrane, clean it with a brush.
Clean the unit once or twice a week.
Clean the water tank and the atomizer with clean water.
Clean the cover carefully and lightly, otherwise it may cause water leaks
through the cover.
After removing water from the atomizer’s surface clean it with a soft fabric.
Clean the unit’s external surface with a damp and soft fabric.
Table 2
Problem
Possible cause
Remedy
Poor atomizing
(insufficient capacity)
The unit is operating in the minimized
mode (low atomizing frequency)
There is no problem. If you need
to switch to the intensive mode of
operation, press « » button and
select the necessary steam outflow
intensity.
The atomizer is clogged
Clean the atomizer
Temperature of water in the tank
is too low
Set maximum capacity. The
humidifier’s capacity will go up
after a while.
Summary of Contents for THU UL 08
Page 9: ...www timberk com 9 1 2 3 4 5 6 7 8 9 10 11 12 9 10 11 11 12 12 13 14 14 15 15 16 imberk 40 60 1...
Page 10: ...www timberk com 10 2...
Page 13: ...www timberk com 13 LCD 10 25 6 40 6 40 50 4 50 60 3 60 1 7 1 7 40 LCD...
Page 14: ...www timberk com 14 8 9 1 2 3 30 50 15 85 3 15...
Page 15: ...www timberk com 15 2 2 3 10 30 2 11...
Page 18: ...www timberk com 18 Timberk c 10...
Page 20: ...www timberk com...