Timberk TGH 4200 M1 Instruction Manual Download Page 5

5.

 

Slowly turning the gas pressure controller (cylinder check valve), make 

sure that no gas leaks are present. For that:
- Lubricate all joints with soapy water. Gas leaks cause formation of bubbles 
in permeable places.
- NEVER USE MATCHES OR LIGHTERS for gas leak checks. 
If you find a gas leak, shut gas and contact your dealer or manufacturer's 
service center.
6.

 

Install the gas cylinder to the dedicated place inside the appliance and 

secure with the clamp.
7.

 

Carry the heater to the supposed place of operation observing the rules 

and precautions described in Section 2 of 

this Instruction 

Manual.

8.

 

The appliance is ready for work.

WARNING!

 All gas joints and pipes should be absolutely tight to exclude even slightest 
gas leaks. Never use matches, lighters, and other sources of open flame for 
leak checks of joints. Use soapy water.
It  is  prohibited  to  use  the  gas-fired  heater  in  flats  of  high-rise  buildings, 
bedrooms, bathrooms, and cellars.
Upon first ignition, it is recommended to preliminarily switch the heater on 
outdoors, after which it can be used indoors.
The  room,  where  the  gas-fired  heater  is  used,  should  be  equipped  with 
natural ventilation.
Do not use the heater during sleep.
Always use only certified, recommended by the manufacturer, and properly 
rated hoses/pressure reducers for connection of the appliance.
Always use only the gas type indicated by the manufacturer.
During  operation  of  the  appliance,  watch  that  the  gas  cylinder  is  always 
strictly  vertical.  Use  of  the  cylinder  in  any  other  position  may  result  in 
occurrence  of  an  emergency  situation,  breakdown  of  the  appliance,  and 
infliction of a significant damage to you and/or your property.
It is prohibited to move or anyhow cover the heater during operation, as well 
as after shutdown, if the heater is still hot.
The heater should be placed for operation so that its face plate is directed 
towards the room center. At that, distances to walls or other objects on sides 
and behind the appliance should be at least 1 m.

Connection to electric mains (for TGH 4200 

O

2 model)

1. The  heater  is  designed  for  connection  to  the  single-phase  220

 

VAC  electric  mains 

equipped with a grounding loop. 
2.  Before  connection,  make  sure  that  specifications  of  the  electric  mains  at  the 
connection point meet the parameters indicated on the appliance nameplate. 
3. Upon connection of the appliance to the electric mains, it is necessary to observe the 
effective rules of electric safety.
4. The electric socket should be properly earthed. The socket should be designed for 
rated current at least 10A. The electric socket and plug should be always dry to avoid 
current leaks. Regularly check that the electric plug is tightly inserted into the socket as 
follows: a) insert the electric plug into the socket; b) in half an hour of operation, switch 
the heater off and remove the plug from the socket; c) check the plug by hand, whether it 
is hot. If the plug has temperature over 50° , replace the socket with another one to 
avoid damage, accidents, or occurrence of fire as a result of poor electric contact. The 
socket should be replaced by a specialist.

ATTENTION

!

The electric socket should be designed for rated current at least 10A and 
an electric cable with wires at least 3x1.5 mm2 in sections (for copper)

7. Control of ceramic gas-fired heater

Ventilation

During  operation,  the  gas-fired  heater  burns  oxygen  contained  in  air  and 
emits carbon dioxide (CO2). 

It is important to remember that operation of the gas-fired ceramic heater is 
permitted only in well ventilated rooms. This allows keeping the necessary 
concentration of oxygen in air and removing combustion products.
Operation of the heater in closed and poorly ventilated rooms may create an 
asphyxiating  atmosphere  and  cause  a  lack  of  oxygen.  If  the  oxygen 
concentration  decreases  below  18%,  the  ODS  system  (oxygen  detector) 
activates and switches the heater off. In this case it is necessary to ventilate the 
room before restarting the heating mode.

ATTENTION

!

Do not start the gas-fired ceramic heater in rooms having volume less 

3

than 84 m . 

2

The minimum area of a vent should be at least 105 cm . 

Necessary air exchange 10m / hour der 1 kW of thermal power heater.

12

www.timberk.com

   

 

 

5

www.timberk.com

   

g

as heater

ENGLISH

2

2

3

1

1

 

 

 

 

-

 

 

 

 

 

,   

 

 

 

     

.

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

 

   

   

 

 

 

   

 1  .

7. 

 

 

 

 

 

 

 

 

 

 

   

   

 

 

 

(

2). 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

   

   

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  18%, 

 

  ODS  (

 

 

 

)   

 

.   

 

 

 

 

 

 

 

 

 

.

   

 

 (

 

 TGH 4200 

O

2)

1. 

 

 

 

   

 

   

 

 220     

 

2. 

 

 

 

 

   

 

 

 

 

 

 

   

 

 

3. 

 

 

   

 

 

 

 

 

 

.

4. 

 

 

 

 

 

 

 

 

 

 

 

 

 

  10 . 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

   

 

 

 

   

 

 

 

 

   

 

   

 

 

 

 

 

 

 

 

 

  50° , 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

.

!

 

 

 

 

 

 

 

 

 

  10 , 

 

     

 

 

 

 3 1,5 

2 (

 

)

!

 

 

 

 

   

 

 

3

 84 

 

 

 

 

 

 

 

 

2

105 

3

 

 10   / 

   1 

 

 

 

.

1. 

 

 

 

 

.

2. 

   

 

 

 

 

 

 

 

   

 (     ) (

 2). 

 

   

 

 

 

 

   

 20-30 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

.   

 

 

 

 

   

 

   

 

10-15 

   

 

 

 

 

 

 

 

 

 

.

3. 

   

 

 

 

 

 

 

 5 

 

 

 

 1-

 

 

 

  

 (

   

 

 

 

 

 (

. 2)

. 2

2

1

1. 

 

 

.

 

 

 

 

 

 

   

 

 

1-  

 (

 «     »), 2-  

 (

 «      »)   3-  

 ( 

 «        »

2. 

 

.

 

 

 

.

2

1

1

3

Summary of Contents for TGH 4200 M1

Page 1: ...3 TGH 4200 SM1 TGH 4200 SM2 TGH 4200 SM3 www timberk com Gas heater Instruction manual Outlook of devices aslo colour scores can be revised without any special advance notices TGH 4200 M1 TGH 4200 O2...

Page 2: ...lacingtheappliancetothepackageforlongstorage 5 When the appliance is not used for a long time keep it in dry cool place in thefactorycardboardpackage 6 WARNING DO NOT COVER THE APPLIANCE when it works...

Page 3: ...rom the electricity supplier for TGH 4200 O2model 34 Technical characteristics of gas which will be used for Timberk gas heaters must be absolutely the same as rating labels instruction manual contain...

Page 4: ...Delivery set 1 Heater on wheeled base 1 pc 2 Gas pressure controller reducer 1 pc 3 Gas hose 60 cm 1 pc 4 Jubilee clips 2 pcs 5 Operation manual 1 pc 6 Warranty certificate 1 pc 7 Package 1 pc NOTE T...

Page 5: ...o the single phase 220 VAC electric mains equippedwithagroundingloop 2 Before connection make sure that specifications of the electric mains at the connectionpointmeettheparametersindicatedontheapplia...

Page 6: ...equirements described in theManual Gascylinderreplacement 1 Makesurethattheheaterisswitchedoff 2 If it is necessary to replace an empty gas cylinder shut gas screwing the gascheckvalveonthecylinderclo...

Page 7: ...preventive cleaning should be carried out periodically to maintain the technical condition of the heater and keep its appearance for long years ATTENTION For your safety it is prohibited to simultane...

Page 8: ...15 40 Timberk Timberk 9 www timberk com 8 www timberk com 16 TGH 4200 O2 180 17 TGH4200 O2 18 TGH4200 O2 19 20 21 22 TGH4200 O2 23 24 25 TGH4200 O2 26 TGH 4200 O2 27 28 29 30 31 TGH4200O2 32 TGH4200 O...

Reviews: