![Timberk SWH FSQ1 100 V Instruction Manual Download Page 10](http://html.mh-extra.com/html/timberk/swh-fsq1-100-v/swh-fsq1-100-v_instruction-manual_1116563010.webp)
www.timberk.com • electrical storage water heater
10
29
NOTE:
When setting temperature, having reached the
optimal heating position « » (+58°С (+/- 2°С), you
will hear a sound signal (for some models).
1.2 Plug the power cord into the outlet.
2. Water heating temperature setting
2.1. Temperature can be set within the range 35°С-75°С, in increments of
1°С. You should use thermostat handle to choose temperature of water
heating.
2.2 The water heater automatically maintains water temperature. When
water temperature in the water heater reaches the temperature, set by the
user, the heating is automatically switched off. When water temperature
in the water heater drops to a certain level, the heating is automatically
switched off.
3. Temperature display (only for FSQ series)
All FSQ series models are equipped with temperature display shows
current water temperature in whater haeter tants.
IMPORTANT!
Water may start dripping from the relief valve hole
during heating. It is impossible to avoid water leakage
and you must not prevent it since valve blocking
may cause rupture of the internal tank (in case of
equipment failure).
Control panel. Timberk FSQ1 and FED1 series
1. Thermostat handle
Please, use this handle to set the desired temperature of water. Turning the
knob in a clockwise direction you increase temperature of water.
2. Switcher of power modes
« » - means OFF position. Turning the knob in a clockwise direction
you increase power from 800W up to 2000W. Only water heaters of FSQ1
series has such option.
3. Indicators lighting (for FSQ1 series only)
If light are blue it means the water heater works, but a water is not heating
inside. If lights are pink/red it means the heating element heats a water
inside tank.
4. LED thermometer
to check temperature inside inner tanks
5. Indicator lamps
in order to see heating mode and power ON mode
Control panel of FSQ1 series
Control panel of FED1 series
8. WATER HEATER CONTROL
Fig. 8
1
2
4
3
Water heater operation
1. Switching on (FED1 and FSQ1)
1.1 At first, open one of the hot water outlet valves, then open the cold
water supply valve. The electric water heater will start filling with water.
When water flows from the hot tap freely, it means the water heater is fully
filled with water and you can close the hot water outlet valve.
NOTE:
During normal operation the cold water supply valve
must be set “open”.