background image

8

www.timberk.com 

    

i

nstant water heater

7. 

WATER HEATER CONTROL

Control panel
WHN-4 OS, WHN-5 OS models

1.  TEST  button

This button is used to test the appliance for 

current leakage.

2.  RESET  button

This  button  is  used  to  reset  testing  of  the 

appliance for current leakage.

3. Power control knob

It  is  used  for  adjustment  of  water  heating 

power.

4.  POWER  indicator

This indicator lights up during water heating.

5.  ELECTRICITY CHECK  indicator

This  indicator lights  up  upon  availability  of 

power supply.

5
4

3

2

1

Fig

. 7

WHP

-4 

OS

WHP

-5 

OS models

Fig

. 8

1.  TEST  button

This  button  is  used  to  test  the  appliance  for 
current leakage.

2.  RESET  button

This  button  is  used  to  reset  testing  of  the 
appliance for current leakage.

3.  ON/OFF  button

This button is used to switch on the appliance

4. Power control knob

It is used for adjustment of water heating power.

5.  POWER  indicator

This indicator lights up during water heating.

6.  E-SAFE  indicator

This  indicator  lights  up  upon  availability  of 
power supply.

7.  EARTH  indicator

This  indicator  lights  up  upon  availability  of 
grounding.

7
6
5

4

3
2

1

Water heater operation

1. Before first start or after a long idle period of the water heater, fill it with 
water opening the cold water feed shutoff valve and make sure that cold 
water steadily flows from the spout at the consumption point.This indi-
cates that the appliance is filled with water.
2. Switch on power supply. The appliance of WHN series will make a self-
test for 2 sec and, if there is no current leakage, the ELECTRICITY CHECK 
indicator will light up on the control panel.For the appliance of WHP series, 
push the ON/OFF button. The appliance will make a self-test for 2 sec and, 
if there is no current leakage, the E-SAFE and EARTH indicators will light up 
on the control panel.
3. Turn the power control knob (Figs. 7, 8) clockwise. The POWER indicator 
will light up (provided that water flow rate exceeds 2.4 L/min) and the wa-
ter heater will start water heating.
4. To check the water heater for current leakage, push the TEST button, 
when  the  water  heater  is  working  in  the  normal  operation  mode. The 
ELECTRICITY CHECK and POWER indicators will extinguish (for WHN se-
ries) or E-SAFE,  EARTH, and POWER indicators will extinguish (for WHP 
series) and heating will be stopped.Push the RESET button to cancel the 
check. The indicators will light up and the appliance will return to the oper-
ation mode.If there is current leakage in the appliance circuit, pushing the 
RESET button will not cancel the leakage test and the indicators will not 
light up. This means that the water heater has problems and it cannot be 
used.During the current leakage test, when the water heater is working 
normally,  if  leakage  current  exceeds  the  defined  value  in  range  from 
7.5mA  to  15mA,  the  indicators  will  not  light  up  and  water  will  not  be 
heated.The appliance can be used only after elimination of current leak-
age.
5. For adjustment of hot water temperature, you can use the valve at the 
inlet connection (cold water inlet) or safety valve.When you decrease inlet 
flow  rate  of  water,  you  increase  outlet  temperature  of  water  and  vice 
versa.To change water temperature, you can also use the power control 
knob (Figs. 7, 8).

NOTE:

Inlet water is heated, when it flows through the heating element 
inside the vessel.Water temperature in the water mains may fluc-
tuate throughout the year from 3°C to 20°C.
To obtain the optimum water temperature, water flow in winter 
shall be made lower than in summer.

Summary of Contents for HP-5 OS

Page 1: ... Models Instant water heater Instruction manual Outlook of devices aslo colour scores can be revised without any special advance notices WHN 4 OS WHN 5 OS WHP 4 OS WHP 5 OS Evolution 4 ...

Page 2: ... disconnect it from the electric mains Perform cleaning and mainte nanceinaccordancewiththeguidelinesofthisinstructionmanual 9 Do not use hazardous chemicals for cleaning of the water heater and excludetheircontactwithit 10 Do not use the water heater for purposes not specified in this instruc tionmanual CONTENTS 1 Importantinformation 2 Precautions 3 Performancedata 4 Waterheaterdesign 5 Packagec...

Page 3: ...tric wires of the device to a water pipeline a gas pipeline etc 24 Make sure in proper connection of electric wiring including connec tiontothegroundingloop 25 Inlettemperatureofwatershallnotexceed 35 C 26 Foruseofthewaterheaterinabathroom itisrecommendedtoinstall itabovebodyheightsothatwatersplashesdonotgetontoitsenclosure 27 Itisprohibitedtosplashwaterontotheheaterorirrigateit 28 ItisPROHIBITEDt...

Page 4: ...t of measure V kW P L min mm kg WHN 4 OS WHP 4 OS shower 220 50 16 3 5 0 03 0 60 2 5 IPX4 I 16 382x250x91 400x260x100 1 8 2 1 WHN 5 OS WHP 5 OS shower 220 50 21 4 5 0 03 0 60 3 2 IPX4 I 21 382x250x91 400x260x10 1 8 2 1 Table1 Specifications SpecificationsofthewaterheateraregiveninTable1 4 WATER HEATER DESIGN The water heater design by the example of WHN series is shown in Fig 1 www timberk com ins...

Page 5: ...tercanbeinstalledinanyplaceprovidedthattemperature intheroomisnotbelow0 C 2 The water heater is installed onto flat wall surface so that water and splashescannotgetontoitsenclosure 3 During selection of a location for the water heater it is necessary to ensure free access to it on the basis of not less than 0 3 m from above from below and sideways This will ensure the maximum comfort of maintenanc...

Page 6: ... sure in the mains exceeds 0 6 MPa the feed system shall be fitted with a reduction valve pressure reducer so that operating pressure does not exceed0 6MPa The water feed shutoff valve shall be installed upstream of the water heaterinlet Fig 4 Installationofashutoffvalveatthehotwateroutletfromthewaterheater isprohibited Fig 5 After installation of the water heater and before connection of power su...

Page 7: ...allation screws and make sure that the cable does not cross sharp edges and does notcontactwithhotsurfaces Connect the electric cable wires with the terminal block according to the appliancemarking refertoFig 6 Make sure that all clamping screws of the terminal block are secured A looseconnectionmayresultinheatingofwires Install the clamping plate of the electric cable to the main position using t...

Page 8: ...ill make a self test for 2 sec and ifthereisnocurrentleakage theE SAFEandEARTHindicatorswilllightup onthecontrolpanel 3 Turn the power control knob Figs 7 8 clockwise The POWER indicator will light up provided that water flow rate exceeds 2 4 L min and the wa terheaterwillstartwaterheating 4 To check the water heater for current leakage push the TEST button when the water heater is working in the ...

Page 9: ... cold The heating indicator Power continues glowing while the water inlet valve is closed The indicators extinguish upon pushing the TEST button the indicators do not light up upon pushing the RESET button Possible causes 1 There is no power supply 2 The temperature limiter at 95 C is tripped or not activated 3 The printed board is faulty 4 Current leakage 1 Water flow rate is less than 2 4 L min ...

Page 10: ...ngdisposalofthewaterheater pleasecontactarepre sentativeofthelocalauthorities Servicelifeofadeviceis5years 10 ELECTRICALSCHEMATICDIAGRAM Fig 9 Terminal block Blue Braun Yellow Green Temperature limiter 95 C Heating element Silicon control unit Water ow sensor Temperature limiter 55 C Indication board RCD Control board Transformer board 10 ...

Page 11: ...11 www timberk com 2 1 2 3 220 50 4 5 6 7 1 2 3 4 5 6 7 8 9 10 11 12 Timberk 0 TIMBERK 1 11 11 12 14 14 15 17 19 19 20 20 20 ...

Page 12: ...12 www timberk com 8 9 10 11 12 13 14 15 16 17 18 19 20 21 28 3 1 2 3 55 95 IN OUT 22 23 24 25 35 26 27 ...

Page 13: ...4 OS 220 50 16 3 5 0 03 0 60 2 5 IPX4 I 16 382x250x91 400x260x100 1 8 2 1 WHN 5 OS WHP 5 OS 220 50 21 4 5 0 03 0 60 3 2 IPX4 I 21 382x250x91 400x260x100 1 8 2 1 1 1 4 2 4 5 1000 3500 WHN 4 OS WHP 4 OS 1000 4500 WHN 5OS WHP 5OS 6 7 TIMBERK ...

Page 14: ...www timberk com 14 www timberk com 4 WHN 1 5 2 1 1 1 1 1 1 1 1 1 WHN 4 OS WHP 4 OS WHN 5 OS WHP 5 OS 2 1 ...

Page 15: ...www timberk com 15 www timberk com 3 3 2 6 1 0 2 3 0 3 4 1 6 5 2 0 03 0 6 0 6 0 6 4 5 3 ...

Page 16: ...4 7 10 2 2 5 G1 2 450 CaCO3 4 1 WHN 4OS WHP 4OS 2 220 WHN 4 OS WHP 4 OS 3x1 5 2 16 WHN 5OS WHP 5OS3x2 5 2 25 3 WHN 4 OS WHP 4 OS 220 4 5 www timberk com 16 ...

Page 17: ...7 WHN 4 OS WHN 5 OS 220 В к контуру заземления 6 6 1 TEST 2 RESET 3 4 POWER 5 Electricitycheck 5 4 3 2 17 www timberk com Рис 7 1 ...

Page 18: ...AFE EARTH 3 7 8 POWER 2 4 4 TEST Electricitycheck POWER WHN E SAFE EARTH POWER WHP WHP 4 OS WHP 5 OS Рис 8 1 TEST 2 RESET 3 ON OFF 4 5 POWER 6 E SAFE 7 EARTH RESET RESET 7 5 15 5 7 8 3 20 WHN 4 OS WHP 4 OS 3 5 16 18 6 7 6 5 4 3 2 1 www timberk com 6 ...

Page 19: ...9 3 8 Power Power TEST RESET 1 2 95 3 4 1 2 4 2 3 55 4 1 2 1 2 1 2 95 3 4 Timberk 1 2 3 55 4 1 2 1 2 Timberk Timberk 19 www timberk com ...

Page 20: ...23308 3 1 323 115162 28 4 74956044266 74956044266 P 60335 2 35 2000 P51318 14 1 2006 4 P51318 14 2 2006p 5 7 P51317 3 3 2008 P51317 3 2 2006p 6 7 RUC IL AB71 B 00051 09 02 2012 08 02 2015 www timberk com 10 88000 972 8 637 88 311 1 1 606 499 638 26 77 7 495 6275285 ...

Page 21: ...Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS 21 ...

Page 22: ...22 ...

Page 23: ...23 www timberk com ...

Page 24: ...www timberk com 71 ...

Reviews: