Timberk AC TIM 05H S9 Instruction Manual Download Page 5

www.timberk.com • Electric air conditioner

5

Model

AC TIM 05H S9

AC TIM 07H S9

AC TIM 09H S9

AC 

TIM 12H S9

AC 

TIM 18H S9

AC 

TIM 24H S9

AC 

TIM 30H S9

Indoor unit

AC TIM 05H S9

AC TIM 07H S9

AC TIM 09H S9

AC 

TIM 12H S9

AC TIM 18H S9

AC 

TIM 24H S9

AC 

TIM 30H S9

Outdoor unit

AC TIM 05H S9-01

AC TIM 07H S9-01

AC TIM 05H S9-01

   

AC 

TIM 12H S9-01

   

AC 

TIM 18H S9-01

    AC 

TIM 24H S9-01

AC TIM 30H S9-01

Max. refrigerant pipe 

length, (m)

15

15

15

15

15

15

15

 Maximum difference in 

level, m

5

5

5

5

5

5

5

Filling of Freon, (g)

410

410

590

700

1200

1450

1450

 Operating temperature 

range: cooling, ° C

+18 ~ +43

+18 ~ +43

+18 ~ +43

+18 ~ +43

+18 ~ +43

+18 ~ +43

+18 ~ +43

Operating temperature 

range: heating, ° C

-7 ~ + 24

-7 ~ + 24

-7 ~ + 24

-7 ~ + 24

-7 ~ + 24

-7 ~ + 24

-7 ~ + 24

Net weight, indoor 

unit (kg)

6,2

6,2

6,2

7

9,3

9,3

14

Net weight, outdoor 

unit (kg)

20,7

23,3

23,4

31

36,7

50,2

52

Gross weight, indoor 

unit (kg)

8

7,8

7,8

8,7

11,8

12,2

17

Gross weight, outdoor 

unit (kg)

22,5

25,3

25,5

35

39,6

54,3

57

Net dimensions, indoor 

unit (mm)

718x240x180

718x240x180

718x240x180

770x240x180

898x280x202

898x280x202

1033x313x202

Net dimensions, 

outdoor unit (mm)

600x500x232

600x500x232

600x500x232

760x552x256

760x552x256

902x650x307

902x650x307

Packing dimensions, 

indoor unit (mm)

805x305x255

805x305x255

805x305x255

855x305x255

995x365x298

995x365x298

1103x400x300

Packing dimensions, 

outdoor unit (mm)

705x550x301

705x550x301

705x550x301

863x585x325

863x585x325

1037x705x433

1037x705x433

Summary of Contents for AC TIM 05H S9

Page 1: ...ores can be revised without any special advance notices AC TIM 07H S9 AC TIM 09H S9 AC TIM 12H S9 AC TIM 18H S9 AC TIM 07H S9 01 AC TIM 09H S9 01 AC TIM 12H S9 01 AC TIM 18H S9 01 Electrical air condi...

Page 2: ...hout any prior notification of customers There may be some misprints in text and digital notations of the present manual If after reading of this manual you have any questions concerning work and oper...

Page 3: ...ditioner during a lighting storm 13 Always unplug the conditioner when it is not used 14 Before cleaning and maintenance of the conditioner unplug it Cleaning and maintenance should be performed in ac...

Page 4: ...900 2700 2675 Power supply V Hz 220 50 220 50 220 50 220 50 220 50 220 50 220 50 Rated current cooling heating A 3 1 2 9 3 6 3 5 4 4 4 3 5 8 5 8 9 8 8 6 13 2 12 3 13 4 12 4 Air circulation indoor unit...

Page 5: ...18 43 18 43 18 43 18 43 Operating temperature range heating C 7 24 7 24 7 24 7 24 7 24 7 24 7 24 Net weight indoor unit kg 6 2 6 2 6 2 7 9 3 9 3 14 Net weight outdoor unit kg 20 7 23 3 23 4 31 36 7 50...

Page 6: ...trol board 2 pcs User manual 1 piece Guarantee slip 1 piece Packing of indoor installation unit 1 piece Packing of outdoor installation unit 1 piece not supplied The conditioner may be controlled from...

Page 7: ...ction of operating mode MODE Using this button you may select a needed operating mode AUTO COOL DRY HEAT FAN Indication of the control board display shall correspond to selected modes Work with remote...

Page 8: ...ess keys Temp will change by 2 The range shift of this threshold is within 2 2 of default temperatures COOL HEAT and FAN 1 Turn the conditioner on pressing the ON OFF button 2 Pressing the MODE button...

Page 9: ...e cleaned more often To remove the filter open the indoor unit panel Remove air filters Clean the filter with a vacuum cleaner or rinse it in clean water If the filter is contaminated heavily clean it...

Page 10: ...he conditioner manufacture is shown in a serial number of the device For more details please ask a shop assistant Upon expiration of the service life the appliance should be utilized in accordance wit...

Page 11: ...www timberk com Electric air conditioner 11 1 11 2 12 3 13 4 15 5 15 6 16 7 18 8 19 9 19 1 1 Timberk...

Page 12: ...www timberk om 12 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Page 13: ...0 7 03 28000 7 85 BTU kW 6600 1 92 7500 2 2 9500 2 78 12500 3 66 18500 5 42 24500 7 18 28500 7 9 600 800 970 1280 2150 2900 2885 640 770 950 1270 1900 2700 2675 220 50 220 50 220 50 220 50 220 50 220...

Page 14: ...5 15 15 15 15 15 5 5 5 5 5 5 5 410 410 590 700 1200 1450 1450 18 43 18 43 18 43 18 43 18 43 18 43 18 43 7 24 7 24 7 24 7 24 7 24 7 24 7 24 6 2 6 2 6 2 7 9 3 9 3 14 20 7 23 3 23 4 31 36 7 50 2 52 8 7 8...

Page 15: ...www timberk om 15 4 1 2 3 4 5 6 7 8 9 10 11 5 1 1 1 2 1 1 1 1 1...

Page 16: ...www timberk om 16 12 13 14 17 15 20 16 19 18 b c d e f 6 on off 1 30 2 30 3 4 on off 10 on off 10 a b c d e f 2 3...

Page 17: ...www timberk om 17 12 ON OFF Power 13 TEMP 14 FAN Auto High Middle Low Auto Low 15 SWING 16 TIMER TEMP 17 SUPER 18 ECO Economic 2 2 19 SLEEP Night Care 1 1 10 20 MODE LR03 8...

Page 18: ...mberk om 18 SUPER TURBO TURBO TIMER TIMER TEMP 20 23 20 26 18 26 23 7 SMART MODE 1 2 Smart Smart Temp 2 COOL HEAT FAN 1 ON OFF 2 MODE COOL HEAT FAN 3 TEMP 4 FAN Smart 5 ON OFF DRY ON OFF MODE DRY ON O...

Page 19: ...www timberk om 19 8 SWING TIMER TIMER TEMP TIMER SLEEP SLEEP Night Care 1 1 10...

Page 20: ...www timberk om 20 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...

Page 21: ...www timberk om 21 TIMBERK c 10 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Page 22: ...www timberk com...

Reviews: