Timberk AC TIM 05H P4 Instruction Manual Download Page 8

7

ENGLISH

NOTICE.

The  unit  can  evaporate  condensed  water  and  automatically  drain  it 
through the hose.
1. When the unit is in cooling mode, it is not necessary to install the 
condensate drainage pipe since condensate evaporates automatically. 
Make  sure  that  when  the  unit  is  operating,  the  rubber  plug  of  the 
drainage hose is securely fixed (see Fig. 10).
2. In heating mode, remove the rubber plug (2) of the drainage hose 
(Fig.  10),  install  the  respective  drainage  hose  to  improve  heating 
efficiency.
3.  In  dehumidification  mode,  remove  the  rubber  plug  (2)  of  the 
drainage hose, install the respective drainage hose.
Disconnect  the  air  outlet  hose,  connect  the  drainage  hose  to  the 
drainage  hole  and  drain  water  from  the  unit  to  ensure  maximum 
dehumidification efficiency.

E4  signal is shown on the LED display at the maximum water level (for 

AC TIM 09HE P

4

). As for AC TIM 05H P4

AC TIM 07H P4

 

and AC TIM 09H 

P4   FULL   indicator is on in this case.
To resume the operation, remove the rubber plug (2) of the drainage 
hose to drain water at first. After water is drained, turn the unit on, the 
unit will resume operation

. 10

6.

 

Maintenance

IMPORTANT!

Disconnect the unit from the mains prior to cleaning.

1. When cleaning the air conditioner, do not use gasoline, solvents and other 

chemically active substances.
2. To avoid electric shock and damage to electrical components, do not pour 

water on the air conditioner from a tap or a hose.

Installation of the filter is performed in the reverse order.

Filter cleaning

At first, carefully clean the filters by means of vacuum cleaners. Then immerse 

the filter in warm water (about 40°C) with a soft detergent, wash it and dry it 

without exposure to direct sunlight.

Air intakes (heat exchangers)

Use a vacuum cleaner for cleaning.
Case
Wipe the surface by a damp cloth and dry it by a soft dry cloth.

Automatic condensate removal

Condensate is automatically removed from the unit. Moisture inside the unit 

starts to evaporate and is removed from the unit through an air duct (or an air 

diffuser) in the form of steam.

www.timberk.com 

 

electric floor standing air  onditioner  ortable type (single case) 

ENGLISH

Fig

. 11

3. Do not use the air conditioner if the power cord is damaged. On the subject 

of replacing a damaged power cord, contact an authorized service center.

Air filter

Air filter clogging with dust particles impairs the air conditioner operation 

efficiency, therefore clean the filter no less than once in two weeks.

Filter removal/installation

Remove the air filter in the direction, indicated by the arrow. Slightly push it 

and then take it out from the device for cleaning. (See Fig. 11).

Fig

.

 

10

Summary of Contents for AC TIM 05H P4

Page 1: ...Timberk AC TIM 09HE P4...

Page 2: ...AC TIM 09HE P4 Instruction manual Outlook of devices aslo colour scores can be revised without any special advance notices Electric floor standing air onditioner ortable type single case 17 18 Electri...

Page 3: ...10 Improper installation and use of this air conditioner may lead to severe injuriesordamagetoyourproperty 11 Any maintenance must be performed by a specialized company and qualifiedspecialists 2 PREC...

Page 4: ...UM4 AAA CR03 batteriesarerequired 1pc 3 The adapter forairduct1pc 4 Airoutlethose1pc 5 Removablegrille1pc only for AC TIM09HEP4 NOTICE The manufacturer reserves the right to make changes in the design...

Page 5: ...hose in the direction indicated by arrow 3 and connectittotheremovablegrill Installationofthehoseincooling heatingmodes Fig 6 To switchthe air conditionertoheatingit is necessary toinstall the hose to...

Page 6: ...the temperature and time are set the display returns to indicating the current temperature 6 FAN speed button Press this button to select low medium high orautomatic fanspeedbutton Whentheautomaticsp...

Page 7: ...on Highfanspeed 8 Mediumspeedbutton Mediumfanspeed 9 Lowspeedbutton Lowfanspeed 2 In the cooling mode one hour after the sleep mode is set the temperature automatically increases by 1 C In two hours t...

Page 8: ...ing the air conditioner do not use gasoline solvents and other chemicallyactivesubstances 2 To avoid electric shock and damage to electrical components do not pour waterontheairconditionerfromataporah...

Page 9: ...doverheatingandriskoffire Donotpullthepowercordwithexcessiveforce itmaydamageit IMPORTANT At high humidity additional condensate removal will be required FULL indicator will go on for AC TIM 05H P4 AC...

Page 10: ...use Troubleshooting method E1 Short circuit on a temperature sensor or a processor board Contact an authorized service center E2 Short circuit between a copper pipe of the temperature sensor and the p...

Page 11: ...1 1 2 2 3 4 5 Timberk 1 2 3 4 5 AC TIM 05H P4 AC TIM 09H P4 AC TIM 07H P4 AC TIM 09H P4 AC TIM 09H P4 6 7 8 9 10 11 6 7 8 9 10 11 2 1 2 3 4 5 6 www timberk com 10 10 12 12 13 14 15 15 17 18 18 18 18...

Page 12: ...11 7 17 32 5 23 8 9 10 3 5 11 10 12 13 14 15 220 230 50 16 www timberk com 1 50 1 2 400 2 3 DF ACTIM 05 M P4 ACTIM 07 M P4 ACTIM09HMP4 1 2...

Page 13: ...50 220 50 220 50 220 50 3 0 2 3 4 1 3 2 5 0 4 3 5 0 4 3 280 280 360 360 25 30 50 50 50 50 52 52 R410 B R410 B R410 B R410 B I class IP 0 I class IP 0 I class IP 0 I class IP 0 22 0 22 5 23 0 23 0 23...

Page 14: ...13 5 AC TIM 05H P4 AC TIM 07H P4 AC TIM 9HM P4 7 1 COOL HEAT COOL HEAT FANSPEED FANSPEED 2 FULL 11 4 3 POWER 6 6 6 C 5 1 2 2 3 3 www timberk com 6 5 A B C...

Page 15: ...14 AC TIM 05H P4 AC TIM 07H P4 AC TIM 09H P4 ACTIM09HEP4 8 1 POWER 2 SET 3 TEMP 1 30 1 25 4 TEMP 1 17 1 15 5 LED 6 SPEED 7 3 4 POWER www timberk com AC TIM 09HE P4 7 8 2 4 5 6 3 1 7 8...

Page 16: ...3 4 ON OFF 4 SLEEP 1 SLEEP 2 1 2 SLEEP 2 2 3 4 3 3 5 9 E4 AC TIM 09HE P4 1 FUNC SET 2 TEMP 1 1 3 POWER 4 SLEEP 1 SLEEP 2 1 2 SLEEP 2 2 3 4 5 1 2 3 ON OFF 1 2 3 ON OFF www timberk com 5 7 6 3 4 2 1 9 8...

Page 17: ...16 6 7 8 9 1 10 2 2 10 3 2 LED E4 AC TIM 09HE P4 AC TIM 05H P4 AC TIM 07H P4 AC TIM 09H P4 FULL 2 10 6 1 2 3 11 www timberk com 11 10...

Page 18: ...17 40 9 7 10 8 AC TIM 05H P4 AC TIM 07H P4 AC TIM 09H P4 FULL AC TIM 09HE P4 E4 10 2 1 2 3 4 10 1 www timberk com...

Page 19: ...18 10 Power 70 LED AC TIM 09HE P4 E1 E2 E4 www timberk com...

Page 20: ...74956044266 52161 2 40 2008 51318 14 1 2006 4 51318 14 2 2006 5 7 51317 3 3 2008 51317 3 2 2006 6 7 RUC IL MP18 B 00006 26 01 2012 25 01 2015 TimberkHomeHeatingAppliancescompanyLtd Hamasgerstr 10 Eila...

Page 21: ...Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS 20 www timberk com...

Page 22: ...21 www timberk com...

Page 23: ...22 www timberk com...

Page 24: ...23 www timberk com...

Page 25: ...www timberk com 17 18...

Page 26: ......

Reviews: