Possible malfunctions and remedies:
If you are not able to remedy a malfunction according to the
recommendations or other malfunctions occur, contact the authorized
service center of Timberk.
11. TROUBLESHOOTING
Malfunction
Cause
Remedy
1. The heater heats poorly
1. The heating element is faulty
1. Contact the authorized service center
of Timberk
2. Low voltage in the electric mains
2. Check voltage in the electric mains
2. The heater does not work
1. No voltage in the electric mains
1. Check presence of voltage in the
electric mains
2. Breakdown of the electric cable
2. Check integrity of the electric cable and
replace it if necessary
3. The automatic circuit breaker of the
electric mains is faulty
3. Check operability of the automatic circuit
breaker of the electric mains and replace
the faulty circuit breaker if necessary
4. Breakdown in the heating element circuit
4. Contact the authorized service center
of Timberk
Temperature
requirements*
Humidity
requirements*
Transportation and
storage
From -30° to +50°
From 15% to 85%
(without a condensate)
Summary of Contents for 82945