background image

3

www.timberk.com

   

i

nstant 

water heater

ENGLISH

.

 OPERATIONAL CHARACTERISTICS

WATERMASTER I Series. Water Heater Models: WHE 3.5 XTR H1, WHE 4.5 
XTR H1, WHE 5.5 XTR H1

1.   Instantaneous water heating without preprocessing and waiting.
2.   Reliable nichrome spiral heating element with ceramic protection; 

the special shape prevents significant accumulation of scale.

3.   Automatic temperature protection (electronic temperature sensor) 

protects water heater from overheating, and assures user protec-
tion against burns.

4.   Hydraulic

 

flow

 

sensor

 

automatically

 

stops

 

the

 

heating

 

mode

 

when

 

cold

 

water

 

supply

 

is

 

suddenly

 

interrupted

 

or

 

water

 

pressure

 

in

 

the

 

system

 

drops

 

below

 the 

working

 

level

.

5.   The water heater is designed for household application, for one 

water consumption point and can be installed in any convenient 
place.

6.   Ultra-thin and space-saving design is ideal for installation and use 

both in a city apartment, and a country-side house. And quicker 
and safer heating combined with notable electric power saving, 
which means less costs, will be pleasing you during the whole life-
time of TIMBERK water heater.

WATERMASTER

 

II

 

Series

Water

 

Heater

 

Models

WHE

 5.0 

XTN

 

Z

1, 

WHE

 6.0 

XTN

 

Z

1, 

WHE

 6.5 

XTN

 

Z

1, 

WHE

 7.0 

XTN

 

Z

1, 

WHE

 8.0 

XTN

 

Z

1

1.   Instantaneous water heating without preprocessing and waiting.
2.   Reliable nichrome spiral heating element with ceramic protection; 

the special shape prevents significant accumulation of scale.

3.   Temperature protection (temperature switch) protects water heater 

from overheating, and assures user protection against burns.

10. Do not use the water heater for purposes not specified in this in-
struction manual.
11. Do not use the water heater in explosive or corrosive environment. 

Do not store gasoline and other volatile highly inflammable liquids 
near the appliance. This is very hazardous!

12. It is prohibited to change the design of the water heater or modify it.
13. Any service works shall be performed by a specialized organization, 

by qualified specialists. Improper installation may result in refusal of 
warranty service.

14. The water heater is not designed for use by people (including chil-

dren) with physical, sensory, or mental disability, having insufficient 
experience and knowledge, without observation and instructing on 
use of the appliance by the person responsible for their safety. It is 
necessary to watch children not to play with the appliance.

15. Do not use the water heater with the damaged electrical cable or 

other damages. For troubleshooting and repairs, please contact the 
nearest authorized service center of the manufacturer in your region.

16. Make sure that the electrical cable does not cross sharp edges and 

does not contact with hot surfaces.

17. Never leave the energized water heater unattended.
18. Do not allow children to use the water heater without supervision by 

adults.

19. Thoroughly observe the connection procedure of the water heater, 

since improper connection will result in its failure and may inflict 
harm to the user.

20. Do not swap locations of the water inlet and outlet positions, since 

this will result in failure of the water heater and may inflict harm to 
the user (see IN (inlet) and OUT (outlet) marks). The water heater 
shall be connected only with its water connections downward in 
strictly vertical  position. Connection of the water heater in another 
position will result in its failure. The water heater shall be operated 
only with the original shower nozzle excluding its clogging.

21. The water heater is designed only for heating of water. Do not use 

the product for heating of other liquids. This may inflict a severe dam-
age to the water heater.

22. Do not connect electric wires of the device to a water pipeline, a gas 

pipeline, etc.

23. Make sure in proper connection of electric wiring (including connec-

tion to the grounding loop).

24. Inlet temperature of water shall not 35°C.

25. For use of the water heater in a bathroom, it is recommended to 

install it above body height so that water splashes do not get onto 
its enclosure.

26. It is prohibited to splash water onto the heater or irrigate it.

27. It is prohibited to: pull electric wires inside the water heater.

ATTENTION!

The water heater shall be certainly grounded.

Summary of Contents for 0 XTNZ1

Page 1: ... aslo colour scores can be revised without any special advance notices WHE 3 5 XTR H1 WHE 4 5 XTR H1 WHE 5 5 XTR H1 WHE 12 0 XTL C1 WHE 18 0 XTL C1 WHE 21 0 XTL C1 WHE 24 0 XTL C1 Heating Mode WHE 5 0 XTN Z1 WHE 6 0 XTN Z1 WHE 6 5 XTN Z1 WHE 7 0 XTN Z1 WHE 8 0 XTN Z1 ...

Page 2: ...ing of cleaning and maintenance of the water heater always disconnect it from the electric mains Perform cleaning and maintenance in accordance with the guidelines of this instruction manual 9 Do not use hazardous chemicals for cleaning of the water heater and exclude their contact with it CONTENTS 1 Importantinformation 2 Precautions 3 Operationalcharacteristics 4 Waterheaterdesign 5 Packageconte...

Page 3: ...installation may result in refusal of warranty service 14 The water heater is not designed for use by people including chil dren with physical sensory or mental disability having insufficient experience and knowledge without observation and instructing on use of the appliance by the person responsible for their safety It is necessary to watch children not to play with the appliance 15 Do not use t...

Page 4: ...piral heating element with ceramic protection the special shape prevents significant accumulation of scale 3 Automatic temperature protection electronic temperature sensor and temperature switch protects water heater from overheating and assures user protection against burns 4 Hydraulic flow sensor automatically stops the heating mode when cold water supply is suddenly interrupted or water pressur...

Page 5: ......

Page 6: ......

Page 7: ...flow sensor 10 Inlet opening for electric cable 11 Wall mounting bracket The design of WATERMASTER III Series water heater is given in Figure 5 6 Fig 5 1 Front panel 2 Control panel 3 Inlet nozzle 4 Outlet nozzle 5 Electronic flow sensor 6 Power board 1 7 Power board 2 8 Temperature switch and pressure sensor 9 Spiral heating element 10 Heating flask 11 Junction block 12 Electronic temperature sen...

Page 8: ...in such a way that a distance from the bottom part of the device to the floor does not exceed 1 6 m Mounting of Water Heater WATERMASTER I Series Water Heater Models WHE 3 5 XTR H1 WHE 4 5 XTR 1 WHE 5 5 XTR H1 As shown in Figure 7 identify the points for openings and drill 2 openings of the corresponding depth in the wall insert dowels screw up the screws and make sure that there is a certain dist...

Page 9: ... drill 2 openings of the corresponding depth in the wall insert dowels screw up the screws and make sure that there is a certain distance between the screw head and the wall then hang the water heater on the screws see Fig 10 and check the reliability of fixing Fig 9 106 mm Fig 10 Fig 12 Fig 13 Fig 11 384 mm 214 mm NOTE Water heater installation at the place of its operation and electric power con...

Page 10: ...s operable let water flow pass through it Check the tightness of all connections and if needed tighten all retaining nuts and screws NOTE Prior to water heater installation flush water supply pipes with flowingwater Fig 14 WATERMASTER II Series Water Heater Models WHE 5 0 XTN Z1 WHE 6 0 XTN Z1 WHE 6 5 XTN Z1 WHE 7 0 XTN Z1 WHE 8 0 XTN Z1 1 Water heater shall be directly connected to cold water sup...

Page 11: ...TL C1 WHE 21 0 XTL C1 WHE 24 0 XTL 1 1 Water heater shall be directly connected to cold water supply line with working pressure from 0 1 to 0 6 MPa If water pressure in water supply line exceeds 0 6 MPa a pressure reducing valve shall be included to the feeding system to assure that working pressure does not exceed 0 6 MPa 2 Water heater has inlet and outlet nozzles for connection to water main th...

Page 12: ...on increase it should be noted that water heater and electric cable shall be located on a thermally insu lated or heated wall 4 For connection to power supply Remove the front panel by unscrewing 2 screws at the device sides Strip the power cord ends by not less than 7 10 mm Pass the electric cable via electric cable inlet opening 10 see Fig 4 at the rear part of the device Remove the clamping pla...

Page 13: ... first water heater start up or after long term non use fill the device with water by opening the cut off tap at cold water supply line and make sure that there is a steady cold water flow at water outlet at the consumption point after that switch on the device power supply 2 Incoming water is heated up inside the heating flask when it is flowing through the heating element Water temperature in th...

Page 14: ...s enough to reopen the water supplying or water draining tap 7 Temperature switch stops the power supply to heating element in the event of water overheating inside water heater If water heater is connected to the electric main and water heating is switched on but water is not heated up it means that the temperature switch has tripped out or was not enabled To return the water heater to operating ...

Page 15: ...the optimum water temperature To switch off the water heater simply close water flow at the inlet to or outlet from the device electronic flow sensor automatically opens the circuit of power supply to heating element and indicating lamp 2 located at the control panel goes down see Fig 15 and power supply indicator 1 starts blinking For the subsequent switching on of heating it is enough to reopen ...

Page 16: ...t light up water is not heated Water is not running from hot water outlet tap Water leakage Water at the outlet from water heater is sometimes hot sometimes cold The heating indicator Power continues glowing while the water inlet valve is closed Possible causes 1 No power 2 Temperature limiting device temperature switch has tripped out or was not enabled 3 Defective printed circuit board 4 Current...

Page 17: ...ntativeofthelocalauthorities Servicelifeofadeviceis5years 10 ELECTRICALSCHEMATICDIAGRAM WATERMASTER III Series Water Heater Models WHE 5 0 XTN Z1 WHE 6 0 XTN Z1 WHE 6 5 XTN Z1 WHE 7 0 XTN Z1 WHE 8 0 XTN Z1 220 50 V Hz thermal cut out R1 connector indicator light R2 K1 K2 heating element WATERMASTER III Series Water Heater Models WHE 12 0 XTL C1 WHE 18 0 XTL C1 WHE 21 0 XTL C1 WHE 24 0 XTL 1 WATERM...

Page 18: ...18 www timberk com 18 www timberk com 2 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 11 12 Timberk 0 TIMBERK 1 18 18 20 22 24 24 29 32 32 33 33 33 ...

Page 19: ...19 www timberk com 6 7 8 9 10 11 12 13 14 15 16 17 18 19 27 20 IN OUT 21 22 23 24 35 25 26 ...

Page 20: ...R H1 WHE 4 5XTRH1 WHE5 5XTRH1 1 2 3 4 5 6 TIMBERK WATERMASTERII WHE5 0XTNZ1 WHE 6 0XTNZ1 WHE6 5XTNZ1 WHE7 0XTNZ1 WHE8 0XTNZ1 1 2 3 4 5 6 TIMBERK WATERMASTER III WHE 12 0 XTL C1 WHE18 0XTLC1 WHE21 0XTLC1 WHE24 0XTLC1 1 2 3 4 5 6 7 LED 1 8 9 TIMBERK ...

Page 21: ......

Page 22: ...3 ...

Page 23: ...23 www timberk com 5 6 7 8 9 10 WATERMASTER II 3 4 3 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 WATERMASTER III 5 6 5 1 2 3 4 5 6 1 7 2 8 9 10 11 12 13 14 1 2 4 11 6 3 4 5 6 7 8 9 10 11 12 13 14 ...

Page 24: ...www timberk com 24 5 1 1 2 1 3 1 4 1 5 1 6 1 0 2 3 0 3 4 1 6 WATERMASTER I WHE 3 5 XTR H1 WHE 4 5 XTR H1 WHE 5 5 XTR H1 7 2 8 7 8 ...

Page 25: ...mberk com WATERMASTER III WHE 12 0 XTL C1 WHE 18 0 XTL C1 WHE 21 0 XTL C1 WHE 24 0 XTL C1 11 4 12 13 WATERMASTER II WHE 5 0 XTN Z1 WHE 6 0 XTN Z1 WHE 6 5 XTN Z1 WHE 7 0 XTN Z1 WHE 8 0 XTN Z1 9 2 10 9 106 mm 10 12 13 11 384 214 ...

Page 26: ...STER I WHE 3 5 XTR H1 WHE 4 5 XTR H1 WHE 5 5 XTR H1 1 0 15 0 6 0 6 0 6 2 10 G3 8 12 G1 2 3 4 14 5 6 450 7 14 WATERMASTER II WHE 5 0 XTN Z1 WHE 6 0 XTN Z1 WHE 6 5 XTN Z1 WHE 7 0 XTN Z1 WHE 8 0 XTN Z1 1 0 15 0 6 0 6 0 6 2 12 G1 2 ...

Page 27: ...erk com 6 WATERMASTER III WHE 12 0 XTL C1 WHE 18 0 XTL C1 WHE 21 0 XTL C1 WHE 24 0 XTL C1 1 0 1 0 6 0 6 0 6 2 12 G1 2 2 12 G1 2 3 4 5 450 6 3 4 5 450 WATERMASTER I WHE 3 5 XTR H1 WHE 4 5 XTR H1 WHE 5 5 XTR H1 1 1 ...

Page 28: ... WHE 6 5 XTN Z1 WHE 7 0 XTN Z1 3x4 32 WHE 8 0 XTN Z1 3x6 40 3 220 4Q 4 2 7 10 10 4 8 4 2 WATERMASTER III WHE 12 0 XTL C1 WHE 18 0 XTL C1 WHE 21 0 XTL C1 WHE 24 0 XTL C1 1 2 380 WHE 12 0 XTL C1 4x2 5 3 25 WHE 18 0 XTL C1 4x4 2 3 32 WHE 21 0 XTL C1 WHE 24 0 XTL C1 4x6 3 40 WHE 3 5 XTR H1 2 220 WHE 3 5 XTR H1 3x1 5 16 WHE 4 5 XTR H1 WHE 5 5 XTR H1 3x2 5 25 3 WHE 3 5 XTR H1 220 4Q ...

Page 29: ...timberk com 3 380 4Q 4 2 1 7 10 13 6 11 6 7 WATERMASTER I WHE 3 5 XTR H1 WHE 4 5 XTR H1 WHE 5 5 XTR H1 1 2 3 20 WHE3 5XTRH1 3 5 16 18 3 4 0 15 2 1 5 10 20 6 7 3 32 WHE 21 0 XTL C1 WHE 24 0 XTL C1 4x6 3 40 2 1 ...

Page 30: ...30 www timberk com WATERMASTER II WHE 5 0 XTN Z1 WHE 6 0 XTN Z1 WHE 6 5 XTN Z1 WHE 7 0 XTN Z1 WHE 8 0 XTN Z1 1 2 3 20 3 0 15 2 3 4 10 20 5 6 2 6 Timberk www timberk com 8 2 1 ...

Page 31: ...31 www timberk com 8 WATERMASTER III WHE 12 0 XTL C1 WHE 18 0 XTL C1 WHE 21 0 XTL C1 WHE 24 0 XTL C1 1 2 3 LED 4 5 6 1 2 1 1 15 2 1 15 3 35 60 4 0 1 2 15 5 10 20 6 3 20 7 2 15 1 3 4 6 5 15 ...

Page 32: ...32 www timberk com 9 4 4 1 2 3 4 1 2 3 1 2 1 2 1 2 3 Timberk 1 2 Watermaster I 3 Watermaster II III 4 1 2 1 2 Timberk 8 Timberk www timberk com ...

Page 33: ...80 50 3 1 2 COM2 COM1 COM3 COM4 PCB1 PCB2 L2 L3 L1 1 2 3 1 2 3 4 5 6 7 8 9 10 R1 R2 R3 R4 R5 10 WATERMASTER I WHE 3 5 XTR H1 WHE 4 5 XTR H1 WHE 5 5 XTR H1 WATERMASTER II WHE 5 0 XTN Z1 WHE 6 0 XTN Z1 WHE 6 5 XTN Z1 WHE 7 0 XTN Z1 WHE 8 0 XTN Z1 220 50 R1 R2 K1 K2 N L G WATERMASTER III WHE 12 0 XTL C1 WHE 18 0 XTL C1 WHE 21 0 XTL C1 WHE 24 0 XTL C1 www timberk com ...

Page 34: ...34 P51317 3 3 2008 P51317 3 2 2006p 6 7 RUC IL AB71 B 00051 09 02 2012 08 02 2015 10 88000 972 8 637 88 311 1 1 606 499 638 26 77 7 495 6275285 www timberk com ...

Page 35: ...35 www timberk com Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS ...

Page 36: ...www timberk com 71 ...

Reviews: