2
3
Unpacking and Initial Assembly
Unpacking your TileVision
®
unit and assembling the back box
Within the back box there are two right-angled brackets – remove the retaining
screws and take them out.
The three positioning holes on the brackets allow the front edge of the back box to
be fitted flush with the front face of the surrounding tiles. The three positions give a
variation of 11mm, 15mm and 20mm from the front face of the back box and will
allow sufficiently precise alignment.
Once the best position has been established, screw the brackets to the sides of the
back box using the retaining screws, as shown below.
Please note –
A technically competent person should carry out the installation
of your TileVision
®
unit.
Installation and positioning
If this has not already been cut, the 23" unit requires a recess of 635 mm x
455 mm and 90 mm depth from the front face of the tiles.
When positioning the brackets you must ensure that there is sufficient depth to
suit your tile and adhesive thickness so as to set the front edge of the back box
level or just recessed from the surface of the tiled surface.
Fit the back box ensuring that the cable inlets are facing downwards and that the
recess in the wall is chased out to accept the cabling. It is essential that all cables
are fed into the bottom of the unit to prevent the incursion of moisture.
With the angle brackets correctly positioned, secure the back box to the wall.
Wall
Flange
Grout
Tile adhesive
Tile
Back box
Plug and screw
or wall bolt fixings
Lead to eathing clamp on cold
water pipe from either of the
earthing points inside the
back box (lead not supplied)
☛
Note: Removal of the front glass requires
a force of 100 lbs using a glass sucker,
therefore, the box must be secured to the
wall in such a manner to easily withstand
such a pulling force.
For further instructions please see inside
the rear of the back box itself.
All cables must be routed into the back
box with 500 mm of cable protruding
before installing as shown above.
If connections for HDMI, S-Video, Audio
and SCART (full) are to be used, then the
wall chasing must allow sufficient room
for the cables.
☛
Note: Your qualified electrical installer must
use one of the earthing strap screws as an
earth point to earth the unit to ground.
The lead used must be terminated with a ring
terminal, which, together with the earthing
strap’s ring terminal, is fastened using the
supplied locking washer and screw.
Installing the Back Box
Example of a back box
installed in a ‘solid’ wall