The speed of the fan can be set in the user menu.
AUTOMATIC VENTILATION FEATURE
The purpose of this feature is to prevent condensation of air under the lid of the heat pump. Ventilation occasionally starts at air
temperatures exceeding 25
°C.
The automatic ventilation feature can be enabled/disabled in the user menu.
1
•
To enter the user menu hold (3 s) field no.
1
.
•
By pressing field no.
1
again, you can move by one step back on each step, thus exiting the
user menu.
•
Parameter group starts to flash.
•
By pressing
+
or
–
select parameter group number 01.
•
Confirm the setting by pressing the symbol.
•
Parameter number starts to flash.
•
By pressing
+
or
–
select parameter number 03.
•
Confirm the setting by pressing the symbol.
1
•
By pressing
+
or
–
set the speed of the fan from 40 to 100% or select automatic adjustment of
the fan speed (Auto). Automatic adjustment of fan speed is not possible in TCA1ZVNT.
•
Store the setting by pressing the symbol.
•
You can exit the user menu by pressing field no.
1
(moves you one step back) or wait for the
unit to exit the menu automatically after a while.
1
•
To enter the user menu hold (3 s) field no.
1
.
•
By pressing field no.
1
again, you can move by one step back on each step, thus exiting the
user menu.
•
Parameter group starts to flash.
•
By pressing
+
or
–
select parameter group number 01.
•
Confirm the setting by pressing the symbol.
•
Parameter number starts to flash.
•
By pressing
+
or
–
select parameter number 02.
•
Confirm the setting by pressing the symbol.