Indicator light: Ac vated status
The X1-siren features an indicator light that shows if the system is ac ve or
not. When the system is ac vated, the LED of zone 4 flashes every 5 seconds.
To switch off the indicator light, while in ac vated mode, press the SET-
bu on for 5 seconds. You hear one beep, and the indicator light switches off.
To switch on the indicator light again, repeat the above-described procedure.
Choosing doorbell-sound or siren sound
In deac vated mode, short press the On/Off-bu on on the X1-siren or the
Loudspeaker-bu on on the remote control to switch between doorbell-
sounds and siren sound. The order of the sounds is
1. loud doorbell
2. mild doorbell
3. very loud siren (120dB)
You hear a short fragment of the selected no fica on sound or alarm sound
each me you press the-bu on.
IMPORTANT: Changes to the X1-siren se ngs can only be performed when
the X1-siren is in deac vated mode. If you try to make changes to the X1-
siren while the system is in the ac vated mode, you hear three beeps.
As a general rule, three beeps always means that the X1-siren is not able to
process the input. Consult the instruc ons for use in such case.
When the siren alarm sounds
When a sensor triggers an alarm in siren mode, the alarm sounds for 2
minutes. Then, the siren stops and the X1-siren returns into ac vated mode
again automa cally. The siren can also be stopped at any me with the
remote control. During an alarm, the LED of the respec ve zone lights up
un l the alarm is switched off.
Stopping an alarm
There are two ways to stop the alarm when the siren sounds. Stop the siren
by pressing the Deac va on-bu on on the remote control.
Alterna vely, you can also stop the alarm on the X1-siren by the following-
bu on combina on: Press 3 mes quickly the On/Off-bu on followed
immediately by a quick press of the SET-bu on.
5. Expanding your system
Expand the X1 system with Tiiwee door sensors and mo on detectors from
the Tiiwee Home Alarm System. It is possible to add up to 10 Sensors
perzone. Up to 10 remote controls can be connected. Furthermore,
addi onal X1-siren units, as well as A3 outdoor sirens, can be connected by
combining the exis ng sensors to the new sirens.
IMPORTANT: Warranty
Connec ng addi onal door sensors
This is an example of connec ng a door sensor to
zone 2:
De-ac vate the X1-siren by pressing the SET-bu on on the X1-siren or the
Deac va on-bu on on the remote control.
On the X1-siren, press the SET-bu on for 5 seconds. You hear a beep and
all four LEDs light up.
On the X1-siren, press the SET-bu on short two mes to select zone 2.
The LED of zone 2 lights up.
Ac vate the door sensor by moving the magnet away from the sensor.
You hear two beeps, and the LED of zone 2 blinks twice.
Save the se ng by pressing the On/Off-bu on on the X1-siren briefly.
The door sensor is now connected to zone 2.
Connec ng PIR mo on detectors
Proceed as described with the door sensors in the previous chapter. Trigger
the device by moving your hand in front of the mo on detector at a distance
of 50-70 cm. When performing the pairing procedure, make sure the mo on
detector is facing downwards from you to avoid unwanted signals from the
device while pairing it to the X1-siren.
Connec ng remote controls
Up to 10 remote controls can be connected to the X1-siren.
Please only use accessories from the Tiiwee Home Alarm System
to ensure a proper func on of the system.