Three Phase EI Inverter
3. Connections
2.2 Inverter Installation
CAUTION - Do not perform these steps when the system is energized. Remove all sources of power during
installation.
!
3.1 Inverter Wiring
3.1.1 Connect EI Link COM cable
1.
Connect one end of the EI Link COM cable (found in EI Link Accessory kit)
to the inverter COM port as shown.
Note: It is easier to make these communication cable
connections before the EI Link is installed.
Slide the inverter onto the top bracket and lock it
with the provided M5 screw from the right side.
3.1.2 Connect CT cable
1.
Connect one end of the EI Link CT cable (found in the EI Link Accessory kit)
to the CT port on the inverter.
CAN1
CAN2
DRM
OFF
COM
BMS
CT
BAT
CAN1
CAN2
DRM
OFF
COM
BMS
CT
BAT
CAN1
CAN2
DRM
OFF
COM
BMS
CT
BAT
CAN1
CAN2
DRM
OFF
COM
BMS
CT
BAT
2. Installation
2.1 Wall Mount Bracket Assembly
Note: You must install the battery base using the EI
Battery QSG before attempting to install the EI Inverter.
Note: If installing the inverter without a battery, mount the inverter bracket on the wall. Proceed to Section 2.2
Note: Open each box and gather the mounting bracket
pieces.
Note: The wall mount bracket is not centered above the
EI BMS. Observe the annotated measurements.
1.5 System configuration
EI Inverter
EI Link
EI BMS
EI Battery
EI Battery
EI Inverter
bracket
Bridge
EI Link
bracket
EI BMS
Quick Start Guide - TSI-6K3D/TSI-10K3D/TSI-15K3D
Pg 2 of 4
1.
Assemble the brackets with provided flange nuts found in the respective
boxes. If the system does not have battery, the inverter bracket must be at
least 200mm above the ground.
2.
Assemble bracket:
•
Connect EI Inverter bracket to Bridge (found in EI Link box).
•
Connect Bridge to EI Link bracket (found in EI Link box).
3.
Place the assembled mounting bracket on the wall so the bottom of the
bracket is 280 mm from the top of the EI BMS. This will ensure adequate
wire management space. Also, the upper right mounting hole should be
shifted 90 mm to the left of the right side of the EI BMS.
4.
Mark mounting holes on the wall.
5.
Remove bracket and drill out wall holes.
6.
Remount bracket to wall using appropriate mounting hardware.
280mm
90mm
PN: 002-00108-00 | REV 2.0 | Oct. 20, 2022