background image

TIGER 

PLUS

CAST-IRON MULTI-FUEL STOVE 

INSTALLATION AND OPERATING 

INSTRUCTIONS

LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER !

THE INSTALLATION AND SERVICING OF THIS APPLIANCE MUST BE SUPERVISED BY A 

QUALIFIED SOLID FUEL ENGINEER. THE SUPPLIERS WILL ACCEPT NO RESPONSIBILITY 

WHATEVER FOR APPLIANCES NOT SO INSTALLED.

 

A register of qualified engineers is available from:

UK: The Solid Fuel Association, 7 Swanwick Court Alfreton Derbyshire DE55 7AS Tel:0845-601-4406 www.solidfuel.co.uk

RoI: Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1 Tel:01-801-5959 www.fireplace.ie

This document is a guide to installing and using the Tiger Plus stove, any 

national or local regulations must be complied with. Building regulations for 

the UK, RoI and IoM can be found at

 

www.tiger-stoves.com

ASBESTOS: 

Tiger does not contain asbestos, but you should be careful to 

avoid disturbing any asbestos when removing an old installation. 

FIRE CEMENT 

is caustic - wash your hands thoroughly after using it. 

WEIGHT

 Protect your spine by moving the stove only with assistance.

FUME EMISSION:

  Properly installed and operated this appliance will not 

emit   fumes   into   the   dwelling.   Occasional   fumes   from   de-ashing   and 

refuelling   may   occur.   However,   persistent   fume   emission   is   potentially 

dangerous and must not be tolerated. If fume emission persists, then the 

following immediate action should be taken:

(a) open doors and windows to ventilate the room. (b) let the fire go out or 

eject and safely dispose of fuel from the appliance. (c) check the flue or 

chimney for blockage and clean if required. (d) do not attempt to re-light the fire until the case of the fume emission has been identified 

and corrected. If necessary seek expert advice

HEAT: 

The surfaces of the appliance and the attached fluepipe will become 

extremely

 hot- a fireguard should be used if children or 

the infirm are present. Flammable materials (including fuel) should not be stored near to the appliance. If the Europa Hi-Leg unit is 

fitted and used as a log store, logs must not be placed higher than the central 'bridging' member.

 BEFORE YOU BEGIN...

CHIMNEY 

Your chimney creates the draught which Tiger needs in order to work - it

 must

:

Conform to local building regulations.

Be at least 5m high.

Terminate at least 1m above any roof ridge.

Have an internal cross-section not less than 0.018m² (eg 150mm dia) and not more than 0.14m² (eg 375 x 375mm)

Be free from even the slightest crack or source of leakage.

Have no bends sharper than 45 degrees.

Be entirely free of obstructions and swept by a qualified chimney sweep.

Be connected only to the one appliance.

Have a wall thickness of at least 100mm throughout its length, or be thoroughly insulated

New masonry chimneys should be fitted with ceramic liners of at least 200mm diameter.

Prefabricated chimneys should be fully insulated, of at least 150mm internal diameter, conform to BS4543 Part 2 and be installed 

in accordance with the manufacturer's instructions.

INSTALLATION CLEARANCES

  The stove must be placed on a solid non-combustible hearth conforming to building regulations. 

There must be no combustible material, including fuel, within: Rear 40cm, sides 30cm. If the Hi-Leg unit is fitted hearth temperature 

will not exceed 100ºC, and light duty hearth material may be used.

LOAD BEARING 

Tiger is heavy - take care to ensure that the floor has adequate load-bearing capacity and consider fitting a load  

distributing plate if necessary

1

Conforms to EN13240

Independently tested by SGS 
Arnheim, 2007
Approved Laboratory No 0608

Fuel

Wood (Beech)

Mineral Fuel

(Ancit)

Efficiency

77.90%

70.30%

Max. Output

6.2kW

6.2kW

CO Emission

(as if at 13% O2)

0.27%vol

0.13%vol

Mean Flue 

Temperature

313º C

286ºC

Clearance to 

combustibles

Rear 40cm

Sides 30cm

Rear 40cm

Sides 30cm

Smoke Emission

77 mg/m³

95 mg/m³

Gas flow

5.4 g/sec

6.3 g/sec

Flue Draught

Min 12Pa

Min 12Pa

THIS APPLIANCE BECOMES 

EXTREMELY

 HOT 

AND CAN PRODUCE 

POISONOUS

 GASES.

A fire-guard should be used if children or the infirm are present. The 

installer is required to EXACTLY follow these instructions and to 

completely comply with all local, national and international standards.

Reviews: