Max/Min/Avg Measuring Function

There are four measuring functions. Press the ‘S’ button to 

change the measurement mode:

    None 

 Max 

 Min 

 Avg.

Data Hold

Press the                 button. The value at the secondary dis-

play will be held, and the LCD will show the HOLD symbol. 

To cancel hold mode, press the                 button again.

Data Review

Press the ‘M’ button when in hold mode to access the data 

memory review mode. The LCD will show the MEM symbol. 

Press the ‘S’ button to review data points zero to twenty. 

Data ‘0’ is always stored in the time interval after auto re-

cording is activated. If the data is automatically recorded, the 

AUTO symbol appears next to MEM during review.

Data Store

Press the ‘M’ button to store the current measurement 

displayed in the Primary Display. The flashing DATA(01~20) 

icon becomes steady for two seconds, then moves to the 

next storage location.

OPERATION CONTINUED

 

 

6

Continued -

Summary of Contents for TIF3710

Page 1: ...UVC LIGHT METER Operator s Manual TIF3710...

Page 2: ...splay 4 Operation 5 Power On 5 Power Off 5 Measurement Value 5 Main Function 5 Max Min Avg Measuring Function 6 Data Hold 6 Data Review 6 Data Store 6 Zero Adjust 7 Memory Clear 7 UNIT Function 8 TIME...

Page 3: ...let lights become very hot during use Severe burns to bare skin can result if it is touched Always turn off the light and wait 15 minutes before removing an ultraviolet lamp Ultraviolet light is very...

Page 4: ...cator Min Max Avg measuring Data Hold Data Review and Data Store functions Over Range Indication HI Zero Adjust Auto Record Memory Twenty points SPECIFICATIONS Sample Time Approximately 0 3 seconds Op...

Page 5: ...CONTROL PANEL LCD Display Select Button Power On Off and Hold Button Memory Button Mode Button 3...

Page 6: ...PLAY 1 Main Functions 2 Primary Reading 3 Data Log 4 Auto Mode 5 Memory Review 6 Data Hold 7 Record 8 MAX MIN AVG 9 Secondary Reading 10 Time Units 11 Measurement Units 12 UV Type 13 Low Battery Indic...

Page 7: ...e button and the tool will shut down Measurement Value The primary display always shows the current reading The secondary display shows the outcome of the advanced func tions or data recording Main Fu...

Page 8: ...ld mode to access the data memory review mode The LCD will show the MEM symbol Press the S button to review data points zero to twenty Data 0 is always stored in the time interval after auto re cordin...

Page 9: ...cord consists of the following values 1 Irradiation intensity 2 Normal or Auto mode 3 Maximum Minimum Average or None 4 Units Zero Adjust Cover the sensor and press the S button to adjust zero The Sec...

Page 10: ...utton to change the measurement units W cm2 or mW cm2 TIME Function Press the S button to set a time interval for auto recording Choose from nine time intervals 1 2 5 10 and 30 sec onds or 1 3 5 and 1...

Page 11: ...h The claim must be made within One Year of the date of purchase WARRANTY 9 Cleaning Using soap and water on a damp sponge or soft cloth clean the housing of the meter IMPORTANT Do not allow mois ture...

Page 12: ...Form No 550404 Rev B August 4 2014 Bosch Automotive Service Solutions LLC 655 Eisenhower Drive Owatonna MN 55060 Toll Free 800 327 5060 Fax 866 287 7222 www TIF com...

Reviews: