Nominal voltage range:SPB 500B/PR/PRA: 50...500 V AC/DC
SPB 1000B/PR:
50...1000 V AC/DC
± 2,5 %
Nominal frequency range:
DC/15... 500 Hz
Input resistance
SPB 500B/PR/PRA:
direct:
195 kΩ at 500 V
switched:
4 ... 7 kΩ
Ri
ELV
:
245 kΩ at 50V
Ri
ELV
:
12 kΩ at 50 V
SPB 1000B/PR:
direct:
261 kΩ at 1000 V
switched:
4 ... 7 kΩ
Ri
ELV
:
335 kΩ at 50V
Ri
ELV
:
12 kΩ at 50 V
Current peak value I
s
direct:
< 4 mA
switched:
< 300 mA
(35 mA at 230 V-RCD-resolution)
On-time:
at max nominal voltage
TRon 120 s
RToff max 240 s (recovery time)
Display
direct: red
-LED for voltage and
phase tester, moving-coil instrument
with large 90° scale and LCD indicator
switched:
additional vibration alarm (PR)
additional acoustic signal (PRA)
for connected load
Phase/
Phase sequence:
capacitive (Test with glove possible)
LED for phase
LED triangles for phase sequence
Polarity:
LCD voltage type - / ~
Continuity:
0 - 1000 kΩ
Power supply:
Voltage tests from the mains
without accu
Functions continuity, phase, phase
sequence by integrated Li-accu
Overvoltage category: SPB 500B/PR/PRA: CAT IV 500 V
SPB 1000B/PR:
CAT IV 1000 V
Surge voltage strength:
>12 kV (1,2/50 µs)
Insulation test voltage: 6 kV
Operating
temperatures:
-15 ... + 45°C
Casing:
unbreakable silicone rubber,
display cover made of
impact resistant polycarbonate
Protection category:
IP 65,
device can be used in moist
environments
Connecting line:
PUR sheathed cable, 1000 V, 1 m
Standards:
IEC 61243-3:2014 + Cor.: 2015
EN 61243-3:2014
DIN-EN 61243-3:2015-08
EMV requirements:
DIN-EN 61326
Dimensions/Weight:
274 x 75 x 47 mm (display part)
B: 380 g; PR: 390 g; PRA: 400 g
9. Technical data