Recommended Surfaces:

 
 

  Thermoplastic Polyolefin (TPO) Membranes 

 

  Polyisocyanurate (ISO)

 

  Expanded Polystyrene (EPS)

 

  EPDM Roofing Membranes 

 

  Ballasted EPDM Membrane

 

  Metal Deck (20 ga. and 22 ga. ONLY)   

 

 Plywood 

Do Not Use on the Following Surfaces:

  ✖ 

Metal Deck less than 22 ga.

    Or over 20 ga. (Structural Deck)

  ✖ 

Loose laid material not part of a complete

    finished system.

  ✖ 

Ice

  ✖ 

Snow

  ✖ 

Tectum Deck

  ✖ 

Concrete

Applications: Surfaces

Roofing Load Requirements

Before the Penetrator X3 and cart are hoisted to any roofing deck the user MUST VERIFY THAT 

THE DECK CAN ACCOMMODATE THE LOAD REQUIREMENTS.

Verify that the surface that the Penetrator X3 will be used on is capable of supporting both the unit and
personnel using it. Inspect that the entire area to determine if the working surfaces have the strength 
and to support users safely.

CAPACITY:

 The Penetrator X3 Mobile Fall Protection System is designed for a maximum of three persons 

for fall arrest and two for fall restraint with a combined weight (clothing, tools) of no more than
310 lbs. per person. No more than four persons may be connected to the Penetrator X3 at any time.
 

IMPORTANT: 

DO NOT start work for which fall protection is required until the Penetrator X3 and

corresponding FRS or PFAS have been completely installed. Do NOT disable any part of the FRS or 
PFAS, including the Penetrator X3 unit, or reposition the unit, until work for which fall protection is
required has ceased. 

Summary of Contents for 72810

Page 1: ...Nickel which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov WARNING This product can expose you to chemicals including Nickel which is known to t...

Page 2: ...Separately Rescue Winch Assembly Purchased Separately Mounting Pins Mounting Frame Spike Engagement Tube Tension Spring Retainer Penetrator Spikes 800 241 1806 404 344 0000 www tiedown com PX3 Fall A...

Page 3: ...ss connectors and a body harness and must include a deceleration system or suitable combinations Note that a PFAS does NOT prevent a fall from occurring The Penetrator X3 can be used as an anchorage i...

Page 4: ...UIREMENTS Verify that the surface that the Penetrator X3 will be used on is capable of supporting both the unit and personnel using it Inspect that the entire area to determine if the working surfaces...

Page 5: ...t Path Cart Path 8 ft Min 15 ft 45 45 45 45 Unprotected Edge or Leading Edge 16 Feet Safe Work Zone Unprotected Edge or Leading Edge 30 Feet Maximum Safe Work Zone After 15 feet the maximum Range of U...

Page 6: ...equipped with lanyards harnesses safety lines etc when working in conjunction with potential fall arrest workers Do not attached fall restraints to the hoisting ring locations Do Not allow the fall re...

Page 7: ...X3 should not be used by persons whose ability or alertness is impaired by fatigue intoxicating beverages illegal or prescription drugs or any other physical cause that exposes the user or others to...

Page 8: ...the rigging gear DO NOT hook to the fall arrest or fall restrain shackle safety line connectors when lifting the cart 3 1 2 Carriage Bolts Install the Permanent Winch Mount From the back side of the P...

Page 9: ...d to use a 1 2 impact wrench for this part of the installation There are two options for installing the permanent roller guide bracket assembly 1 Access the nylock nut by working from the top inside a...

Page 10: ...cue hook should pass under the roller and about the bottom of the roller bracket WARNING Be careful not to come in contact with the five penetrating spikes 3 1 4 Clevis Pin 3 1 2 Carriage Bolts Safety...

Page 11: ...A WORKER WHEN NOT BEING PROPERLY CONNECTED TO AN APPROVE ANCHORAGE CONNECTION CAN RESULT IN SERIOUS INJURY INCLUDING DEATH Workers must be properly trained in the use of the Tie Down Rescue System PR...

Page 12: ...d off to the Penetrator X3 Using a rescue pole attach the hook cable to the fallen worker If the cable length and ground conditions allow it is recommended to lower the worker safely to the ground If...

Page 13: ...deployment as the result of an fall incident make certain that the rescue procedure has been successfully completed The five penetrating spikes will be somewhat buried into the roof after activation F...

Page 14: ...tems This certificate declares that the above standard s was met by the requirements of such standard s Testing was performed under normal operating measures The results of testing apply only to the s...

Page 15: ...on the employee to 1 800 pounds 8 kN 1910 140 d 1 ii Bring the employee to a complete stop and limit the maximum deceleration distance the employee travels to 3 5 feet 1 1 m 1910 140 d 1 iii Have suff...

Page 16: ...l Cart Parts Date Corrective Action Taken Penetrator X3 Device Frame Free of Rust Frame Welded Connections Mounting Pins 2 Penetrator X3 Spikes Free of Damage Spike Guard Shield Present Anchor Shackle...

Reviews: