Tidland 900 KA Series Operation & Maintenance Manual Download Page 3

 

 

 

3

To Replace the O-rings on the O-ring Connector: 
 

1.  Locate the O-ring connector inside the valve journal. 

 

2.  Using a deep-well socket, remove the O-ring connector. 

 

3.  Remove the used O-rings (2). 

 

4.  Place new O-rings (2) on the O-ring connector. 

 

5.  Add a light layer of non-curing sealant to the O-ring connector threads. 

 

6.  Insert the O-ring connector into the valve journal. 

 

7.  Tighten using a deep-well socket. 

 
 

To Install the Internal Bladder Assembly into the Shaft: 
 

Note:  Due to the retraction of the internal leaves, the external leaf may need to be held 

in the expanded position for ease of installation of the internal bladder. 
 

a.  Remove a few button head cap screws from the external leaves. 
b.  Form a bridge across the leaf to allow tightening of the bolt to lift the leaf enough to allow 

clearance. 

c.  Make sure that the bolt slots are not scratched or damaged. 
d.  This may need to be completed in several places. 

 

1.  Slide the non-valve end of the bladder assembly back into the shaft body. 

 

2.  Push the valve end of the bladder assembly into the valve journal. 

 

3.  Place the valve journal in the shaft.  

 

4.  Loosen and remove the bolts from the jacking threads. 

 

5.  Replace the bolts in the tapped holes in the shaft body. 

 

6.  Tighten the bolts to secure the valve journal. 

 

7.  Remove all items used in the bridge across the leaf to hold the leaves expanded. 

 

8.  Apply a locking compound to the button head cap screw threads. 

 

9.  Replace all the button head cap screws that connect the external leaves to the internal 

leaves. 
 

10.  Inflate the shaft and check for leaks. 

 

11.  Replace the air valve. 

 

In

 

the United States 

 

 

In the United Kingdom  

In Germany 

 

Tidland products are 

Tidland Corporation 

 

 

Tidland (UK) Ltd. 

 

Tidland GmbH 

 

also manufactured in: 

P.O. Box 1008 

70-72, Manchester Road 

Siemensstrasse 13-15   

Keene, NH U.S.A. 

Camas, WA 98607 

Denton, Manchester 

D-48683 Ahaus 

 

Sao Paulo, Brazil 

U.S.A. 

UK M34 3PR 

Germany 

 

 

Sydney, Australia 

Phone: 1-800-426-1000 

Phone: 161.320.2000 

Telefon: 02561-6880 

 

Tokyo, Japan 

            1-360-834-2345 

Fax: 161.320.4513 

Fax: 02561-6495 

 

Mumbai, India 

Fax:     1-360-834-5865 

Email: [email protected]  

Email: [email protected] 

Email: [email protected] 

 

 

Web Site: www.tidland.com 

 
© 1998 Tidland Corporation 

 

Rights reserved to amend technical details without notice 

518915 

September 1998

 

Reviews: