Appendix I  Lightning and Surge      

                                             

Outdoor Dome Camera need to consider lightening, anti-surge, on the premise of 

ensuring electrical safety, may take the following measures

 

 

Signal transmission lines and high voltage equipment or high voltage cables must be 

at least 50 meters distance between

 

 

Try to choose outdoor wiring along the eaves line

 

 

For open field must be sealed steel tubes buried cabling, grounding and steel pipe, 

the absolute prohibition of the use of overhead wiring

 

 

In areas of severe thunderstorm or high-voltage area (such as high-voltage 

substations), lightning protection equipment, as well as for additional installed power 

must be taken measures such as installing lightning rods 

 

Outdoor lightning protection and grounding design of devices and circuits must be 

combined with building mine requires unified consideration and in accordance with 

the requirements of the relevant national standards, industry standards

 

 

System must be equipotential earthing. Earthing system anti-interference must be met 

and the dual requirements of electrical safety, and shall not be mixed with strong 

power network neutral wire shorted or. Separately when grounding, grounding 

impedance less than 4 ohms, ground wire cut-area must be not greater than 25mm2 

lines shorted 

 

Summary of Contents for TC-NC SERIES

Page 1: ...ponents and accessories does not mean that the standard configuration of equipment detailed configuration please refer to the packing list All text forms and images of this manual are subject to national laws to protect information prohibition of unauthorized diversion Service Instructions Note In the product warranty period the company provides free repair service but are subject to the following...

Page 2: ...y heat sources such as heaters and heating can cause excessive heat or fire When you have completed the wiring disassembly and assembly operations such as unplugging the power supply not charging plug Has not completed all the installation work do not power on When you are installing the product ensure the product is firmly seated caused by installing loose responsibility our company is not respon...

Page 3: ...e transmission process if necessary take anti lightning anti surge and other protective measures Ignore may interference the image by electromagnetic fields and damage the product Do not use camera aim at strong light objects such as sun light filament lamp otherwise it will cause unrecoverable damage to the camera CCD Under the cover are advanced optical devices please avoid direct hand touch in ...

Page 4: ...erface and cable colors are as following IR High Speed Dome High Speed Dome AC24V1 DC24V Red AC24V1 DC24V Green Lightning protection Green Yellow 485A Blue 485B Black Ground Green 1 Audio input Purple Audio Ground Green2 Audio output Yellow Alarm input Yellow 1 2 3 4 5 6 7 8 Alarm Ground Green 3 Alarm output 1 Normally open White 1 Alarm output 1 Public White 2 Alarm output 2 Normally open White 3...

Page 5: ...actually required to prepare your own tools Confirm that the site has enough space to accommodate the installation of the product and its structure Confirm the installation of PTZ ceiling wall bracket carrying capacity must be able to support the dome and the total weight of the mounting structure Require a four fold safety factor Unpack the PTZ packaging please keep the original packaging materia...

Page 6: ...owser to confirm download successfully Notice Please use the IE browser of Windows operating system confirm the version is above 6 0 Please don t use any third party browser and any IE browser shell like Maxthon FireFox Window of the World we do not ensure use these software can log on the network video server Open IE inputting the IP address in address bar Then click go to it ll show up as follow...

Page 7: ...hange the IP address from network video browser parameter configuration network parameters cable setting Tick automatic acquisition IP address option for automatic acquisition IP Need according to actual condition to set if manually input the IP as below figure input the adjustment IP address click Setting then product will automatic restart after IP setting successfully ...

Page 8: ...such as high voltage substations lightning protection equipment as well as for additional installed power must be taken measures such as installing lightning rods Outdoor lightning protection and grounding design of devices and circuits must be combined with building mine requires unified consideration and in accordance with the requirements of the relevant national standards industry standards Sy...

Page 9: ...custom flange interface customer can custom high speed dome bracket Note The interface size between IR high speed dome and high speed dome is same so in the configuration list use the same type of wall or pendent bracket Interface size figure for high speed dome and arms ...

Reviews: