Troubleshooting

TROUBLESHOOTING

The unit is not turning on 

•  Check whether the unit has been turned on. 
•  Check the power supply (try a different power source/vehicle/socket). 
•  Check whether the plug and the socket have a good connection.
•  Check whether the fuse has been burned out or blown.

Low refrigeration performance 

•  Too much product has been placed inside the unit.
•  There is too much warm product inside the unit.
•  The lid is unlatched or open.
•  The lid seal is broken.
•  Poor ventilation (allow 100mm of space around all vents).
•  The ambient temperature is too high.
•  The temperature setting is too high.

Can hear the sound of running water from inside the unit

•  This is normal, due to the flow of refrigerant in the unit. 

Unusual noise when refrigerator is working 

•  The refrigerator is not placed on a level surface. 
If none of the above solves your issue please contact 
Thunder at thunderauto.com.au or thunderauto.co.nz.

Yellow fault light flashing

 ER 1 flash every 4 seconds - low voltage: 

 

 

•   Try on different power source (vehicle or 240V AC power). If changing 

power source fixed issue, then possible issue with original power source. 

•   Ensure cabling between fridge and battery is at least 4mm, if the distance is 

more than 2 metres then use at least 6mm cable.

 ER 2 flashes every 4 seconds - fan issue: 

 

 

•  Fan is drawing too many amps (over 0.5 amps), replace fan.
 ER 3 flashes every 4 seconds - compressor start issue:   
•  Unplug cable and allow unit to rest for 10 minutes.
•  Try on different power source (vehicle or 240V AC power).
•  Electronic box fault.
•  Compressor fault.
ER 4 flashes every 4 seconds - low motor speed:
•  Reduce products/items inside unit.
•   Move so unit is in a lower ambient temperature, clean vents/ensure clear air 

flow over compressor.

•  Fan fault.
ER 5 flashes every 4 seconds - over temperature:
•  Ambient temperature too high.
•  Clean vents/ensure clear air flow over compressor.
•  Fan fault.

Summary of Contents for TDR02101

Page 1: ...1 For your personal safety read understand and follow the information provided in this instruction manual CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER 60L FRIDGE FREEZER...

Page 2: ...4 External Internal Dimensions 5 Product Specifications 5 Operation 6 LED Control Panel 7 Smart Phone App Instructions 8 Cleaning Maintenance 9 Troubleshooting 10 Warranty Terms Conditions 10 Certifi...

Page 3: ...posed Do not attempt or continue to operate your unit if it is wet 1 Your unit requires good ventilation especially around the vents of the refrigerator allow a gap of at least 100mm around all vents...

Page 4: ...n handles 4 Digital display operation screen and USB outlet panel 5 Two way opening lid 6 Bottle opener 7 LED interior light 8 Divided compartment storage 9 Can hold up to 60 x 375mL cans 10 Wi Fi ena...

Page 5: ...CATIONS SPECIFICATIONS EXTERNAL DIMENSIONS 445 H x 800 L x 455mm W WEIGHT 26kg empty INTERNAL DIMENSIONS LARGE BASKET 325 H 390 L x 340mm W CURRENT DRAW 3 3 6A INTERNAL DIMENSIONS SMALL BASKET 140 H 1...

Page 6: ...s to achieve Press the button to increase or the button to decrease the temperature Press the Turbo button for Turbo mode to increase the speed of the compressor This setting can be used when you need...

Page 7: ...the QR code on the inside of the fridge scan with your phone and your Thunder Fridge is ready to go Now that you are linked to your Thunder Fridge you now have the ability to Easily switch between fri...

Page 8: ...ean the unit Never use abrasive products detergents soap or hard objects during cleaning as these can damage the unit After cleaning wipe out with a clean damp cloth and dry carefully Never clean the...

Page 9: ...es your issue please contact Thunder at thunderauto com au or thunderauto co nz Yellow fault light flashing ER 1 flash every 4 seconds low voltage Try on different power source vehicle or 240V AC powe...

Page 10: ...or replace the unit This warranty does not apply to failure or damage to a Thunder product caused by incorrect or faulty fitment accidental or intentional damage failure of other products incorrect ap...

Page 11: ...attery system to manage solar and in vehicle charge Featuring a 7 stage smart charger to maintain battery condition the unit is compatible with leading vehicle batteries including Lead Acid Calcium Ge...

Page 12: ...12 GPC Asia Pacific Pty Ltd ABN 97 097 993 283 51 57 Qantas Drive Brisbane Airport QLD 4007 AUSTRALIA thunderauto com au thunderauto co nz...

Reviews: