4.

 

寸法(

mm

Dimensions 

(All Dimensions in mm) 

             

 

Cable type: SOOW, 18/3C AWG, 1-3 m length

 

5.

 

組立と設置(設置する場合は照明器具を開かないでください)

   

                   

Assembly and Installation (The luminaire shall not be opened during installation) 

5.1

 

ブラケットの取付

 

Mounting Bracket Installation 

5.1.1

 

両用

(

壁掛形

/

天井取付形

)

型式

Two Position Adjustable Trunnion (Wall & Ceiling) Mounting 

 

取付ブラケットは壁掛形(

Figure1

)と天井取付形(

Figure 2

)に使用できます。

 

 

ブラケットホルダーを付属の

M8

ネジで

600 N-cm

のトルクで固定します。

 

 

4

つの留め具(付属していません)を使用して壁掛

/

天井取付金具を構造に固定します。

 

 

照明器具の角度は微調整が可能です。

 

 

The mount bracket is for the use of both ceiling mount (Figure 1) and wall mount (Figure 2).

 

 

Position the bracket holders and secured by means of the provided M8 screws, 600 N-cm.

 

 

Secure the wall/ceiling mounting bracket to the mounting surface by using four fasteners

 (

not provided).

 

 

The angle of luminaire can be adjusted.

 

 

 
 
 
 
 

Figure 1 

Figure 2 

Summary of Contents for L1512

Page 1: ...ing Model L1512 Contents 1 General Safety Instructions 1 2 Intended Field of Application 2 3 Technical Data 2 3 4 Dimension 4 5 Assembly and Installation 4 6 6 Maintenance 7 7 Accessories and Spare Pa...

Page 2: ...nstructions WARNING This manual contains basic safety instructions to be observed during installation operation and maintenance of the apparatus and for properly and safety run of the apparatus accord...

Page 3: ...015 Rating THTH1512ANK 1N0 110 Vac 50 60 Hz 140 W THTH1512ANK 1Q0 110 Vac 50 60 Hz 160 W THTH1512ANK 1S0 110 Vac 50 60 Hz 180 W THTH1512ANK 1U0 110 Vac 50 60 Hz 200 W THTH1512ANK 2N0 220 Vac 50 60 Hz...

Page 4: ...o compress the Tube at the factory Cable gland is for circular round non metal sheathed cables The cable type is SOOW 18 3C AWG 1 3 m length Size of Tube 9 0 Fitting Cable OD 9 L 15 mm Mounting Type W...

Page 5: ...ion Adjustable Trunnion Wall Ceiling Mounting Figure1 Figure 2 M8 600 N cm 4 The mount bracket is for the use of both ceiling mount Figure 1 and wall mount Figure 2 Position the bracket holders and se...

Page 6: ...t with 2700 kgf cm Tighten tube locking setscrew to conduit 1 0 N m Figure 3 5 1 3 Bending Electrical Tube Mounting M35 NPT1 1 2 M35 NPT1 1 2 6600kgf cm 1 0N m Figures 4 and 5 The bending electrical t...

Page 7: ...D current 1 0A V 110Vac 10 Both ground screw and washer material is stainless steel Screw hole spec M5 Torque requirement 14 5 kgf cm Ensure wire is tied assured 5 3 Putting into Service Before puttin...