THT-EX L1319 Operating Instructions Download Page 3

3

(3) Model name, 1319 = Model L1319 series
(4) Sub-series designation , Z = No sub-series under this model
(5) Designates type of Top Cover, C = Top Cover with opening
(6) Designates type of LED module, C = LED bar
(7) Designates C.C.T of LED, C = Cool white, W = Warm white
(8) Designates voltage, 2 = 220 Vac, 1 = 110 Vac
(9) Designates wattage of LED lighting, D0 = 40W
(10) Mounting type, W90 = Wall mounting

H90 = Hanging mounting
C90 = Ceiling mounting
S25 = Stanchion mounting 25°
P90 = Pendant mounting

5.   Dimensions

(All Dimensions in mm) – Subject to Alterations

6.

Assembly and Installation

6.1 Electrical Connection

Overview

1: Junction Box ( Provide by customer)

2: Cable (Length(min):1.5 m)

3: L1319 Lighting

Electrical Connection

1.

Insert the cable (2) of the luminary into the Ex certified Junction Box (1).

2.

Fix  and  Introduce  the  wires  of  luminary  with  the  terminal  post  of  Junction  Box  (White-wire  connects  to
Neutral; Red-wire connects to Live; Green-wire connects to Ground.)

Attention:

1. The Junction Box must be pass the Ex db/Ex tb certification that approved by IECEx/ATEX.

2. The minimum diameter of suitable cable for cable gland is 7.5 mm.

3. The cable types are: SJTW or SOOW, 18/3C AWG, 1 m length.