WWW.THOROUGHCLEAN.COM.AU
Machine is now running, pump is pumping and system is in by-pass (until trigger on gun
activated from closed to open = high psi flow)
Note:
‘C’ is the throttle which controls the REV’s. This has been pre-set and locked. Do
not attempt to change this. It has been set according to pump specs.
Your unit is now ready to perform a trial high pressure blast. Depress the trigger
on the gun pointing the lance in a safe direction. Always test using a new H.P Jet
(#1506)
OPERATING/CLEANING TIPS:
1. Using a Fan Jet, first blast off heavy soil or dirt build-up
2. Apply detergent to partially cleaned surface using low pressure. (Apply
detergent by spraying from bottom up to avoid streaking - using a dual-lance
and detergent assembly or foaming lance or separate pressure sprayer.)
Allow to soak for a few minutes.
3. Blast off dirt using high pressure and a 'bottom - up' approach.
4. Lastly, rinse off thoroughly with 'top down' approach.
NOTE:
During the first 10 to 12 hours of operation, manufacturing debris like SWARF /
LOCTITE may come through the machine and cause blockages of the H.P. Jet.
Remove and clean if this occurs.
TO SHUT DOWN:
1. Flick the main ON/OFF switch back to the OFF position.
2. Turn off fuel supply off by pushing the fuel supply lever all the way to the
LEFT.
3. Turn water supply off and disconnect from water supply.
4. Squeeze the trigger a few times to ensure no pressure is stored in the
system.
5. Roll out the hose and then roll up avoiding any kinks.