Chapter 3: Installing the system
14
General installation requirements
3.1 General installation requirements
The GMDSS system can be installed separately or in a dedicated console. For
information on how to install the system in the console, see the installation
manual for the SAILOR System 6000 Console
.
3.1.1 Power requirements
A SAILOR 6110 GMDSS System operates on either 115 VAC, 230 VAC or a 24 V
floating DC (nominal value). The SAILOR 6081 PSU and Charger provides
automatic switch over to a battery supply in case a drop out occurs in the
Mains supply.
Power consumption
The total power consumption varies primarily due to system activities. Make
sure the backup battery is capable of providing the required power. As a
guideline, note the power consumption of the following equipment:
Important
Only the SAILOR 3027 GMDSS Terminal must be placed
outdoors.
Place all other units in the system indoors!
For
information on environmental requirements to the units, refer
to
on page 61 or the individual
installation manuals for the units.
Unit
Idle power
Max. power
SAILOR 3027 GMDSS Terminal
1.85 W @15 V DC
30 W @15 V DC
SAILOR 6006 Message Terminal
(12 V DC - 24 V DC)
12 W
20 W
SAILOR 6101 Alarm Panel
1 W
2 W
SAILOR 6103 Multi Alarm Panel
1 W
4 W
Summary of Contents for SAILOR 6110
Page 1: ...INSTALLATION MANUAL SAILOR 6110 GMDSS System...
Page 2: ......
Page 36: ...Chapter 3 Installing the system 26 Mounting the SAILOR 1252 printer...
Page 66: ...Chapter 5 Installation check and test 56 Generating a diagnostic report...
Page 78: ...Glossary 68...
Page 81: ......
Page 82: ...98 130752 A Thrane Thrane A S info thrane com www thrane com...