ThoroughClean D10i-36C Operator'S Manual Download Page 14

Claim Procedure: 

Contact ThoroughClean by phone or e-mail informing us of your pressure cleaner's 
problem or defect. 

Once the extent of the claim has been assessed, we retain the right to compensate the 
consumer for such defect, or repair (pars & labour), or replace the machine under warranty. 

All warranties will be carried out by ThoroughClean authorised staff or appointed agents at 
a premises to be determined by the Manufacturer.  

It is the responsibility (and cost) of ThoroughClean or our appointed agent to return the 
machine to be repaired or replaced under warranty to the consumer – this is valid for 
Australian territories only. 

Where the specific warranty component (e.g. engine) is a Manufacturer's warranty other 
than ThoroughClean (e.g. HONDA), the consumer can either contact ThoroughClean or the 
applicable Manufacturer for repairs where such warranty was registered with that 
Manufacturer at purchase.  

Warranty calls will only be carried out during normal working hours and only by our 
representatives and not via client's choice of repairer. We will not accept back charges for 
any work not carried out by our representatives, or accept any charges due to equipment 
being un-operational for any reason even during its warranty period.  

 

THIS WARRANTY WILL NOT APPLY TO: 

 

Any part/component that has been subject to misuse, negligence, accidental damage, 
improper or inadequate maintenance or improper storage. 

Any part that has been subject to misuse, negligence, accidental damage, improper or 
inadequate maintenance, or improper storage. 

Repair rendered necessary or arising from the use of parts or components other than 
approved by the manufacturer in writing.  

Normal maintenance, replacements of service and consumable items including but no 
limited to nozzles, seals, oil, guns, swivels, filters, by-pass valves and HP hose.   

Deterioration of any item due to normal use, fair wear and exposure unless due to a defect 
in material or workmanship.  

Any work or adjustment performed by persons other than authorized ThoroughClean 
service staff or authorized dealers or damage resulting there from. 

Any damage that results from operating methods other than those indicated in the owner's 
manual, or use beyond the limitations or specifications as published in the Specification 
Sheets of the particular model.  

 
 
 

WARRANTY CONTACT INFORMATION: 

Tel +61 (07) 5467 2025 

Fax +61 (07) 5467 2026 

[email protected] 

12 Ashburn Road, Bundamba, Queensland 

4304, Australia 

 
 
 

SERVICE & PART ORDERING 

 

For service and ordering parts, please call 1300 378 872 or 07 5467 2025 

 

Or your nearest ThoroughClean Distributor 

 

We have very knowledgeable, experienced staff to assist you with help and advice. 

 

14 

Summary of Contents for D10i-36C

Page 1: ...ndex Page 2 Technical data Specifications 3 Installation Start up 4 Operating Tips Shutting down Regular Checks 5 6 Maintenance Schedule 8 9 Trouble Shooting Guide 10 What can cause expensive damage t...

Page 2: ...00 psi 15 lpm 3000 psi 15 lpm 3000 psi 15 lpm Nozzle size at set up pressure 15045 15045 15045 15045 Pump Speed RPM 1450 1450 1450 1450 Hour Meter Engine Pump vibe mounted Pump protected by LubeBuddy...

Page 3: ...there are no kinks in it Trigger gun to expel any air in the system LAST CHECKS START Check all hoses are connected and check for damage or water leaks Check oil level in the pump The oil sight glass...

Page 4: ...vy soil or dirt build up The unit comes standard with a 15 degree nozzle correctly sized for the pressure and flow for your machine Always use the same size nozzle NEW to test the machine for performa...

Page 5: ...diately Do not use extension cords on these units plug straight into wall socket SAFETY Ensure safety protective gear is used and in good state of repair Ensure Safety MEDIC ALERT Card is handy Prolon...

Page 6: ...3 pump Replace Brass Valves 6 pump Replace various seals 3 pump Replace Ceramic Piston Plungers if cracked or worn 3 pump Only if required 12 Check By Pass valve function test re kit or replace if req...

Page 7: ...uneconomical to repair Replace as necessary Remember to check filters regularly and clean under running water The correct procedure for replacing the filter mesh in the small black filters vs the larg...

Page 8: ...k suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger Excessive pressure and or temp in the pumped water Check the temperature and pressure of inlet water SHO...

Page 9: ...eals Worn Cracked Piston Check Replace Water Blasted into Pump via Breather Cap during Cleaning Exercise Care WATER DRIPPING FROM UNDER PUMP Between crankcase and manifold housing H P Piston Seals Wor...

Page 10: ...t through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power COMMON MISTAKE Put a smaller HP Jet onto lance for higher pressure When orifice is reduced...

Page 11: ...etration would be detrimental NEVER WATER BLAST fragile items surfaces that may be damaged by high velocity water Always carefully test on a small area first ALWAYS WEAR PROTECTIVE GEAR PPE i e Head f...

Page 12: ...t task was being performed at the time of the injury making special note of any chemicals that were used and the quality of the water MEDIC ALERT INFORMATION ALWAYS ENSURE MACHINE IS FITTED WITH A REM...

Page 13: ...tion for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a maj...

Page 14: ...period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been sub...

Page 15: ...he required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen cir...

Page 16: ...6 38 37 34 26 40 41 42 1 29 33 6 10 9 8 13 12 14 20 19 11 43 44 45 48 31 32 23 16 25 30 15 16 17 18 27 46 47 24 3 28 7 4 2 26 25 23 16 21 22 13 14 11 18 12 5 Hawk NPM1525 serie 2011 NPM1525 pump 2011...

Page 17: ......

Page 18: ...02 00 Valve plate 6 21 0900 30 Valve spring 6 22 0604 05 Valve cage 6 23 1802 03 Hexagonal screw M8x18 8 24 0500 61 Closed bearing housing 1 25 0601 63 O Ring 1 78x60 05 2 26 0200 06 Roller bearing 33...

Page 19: ...Seals 18 mm 1 2600 37 Complete Seals Packing 18 mm 3 2612 42 Plunger 18 mm 3 2600 08 Complete Valve 6 2608 03 Plunger oil Seals 1 2600 75 Complete Manifold 1 3100 13 Connecting Rod Plunger Rod Assy 3...

Page 20: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Page 21: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Page 22: ......

Page 23: ...3 3 4 4 5 5 6 6 A A B B C C D D D10R Circuit Diagram A Ferero D Cover 23 11 2011 Designed by Checked by Approved by Date 1 1 Edition Sheet Date To TVE Fuel sol 86 87 87A 30 85 E Stop Float TVE from h...

Page 24: ...STARTER SOL VE R1 WATER FLOAT SWITCH R3 R3 WATERFAULT LIGHT R2 OIL PRESSURE SWITCH ENGINEFAULT LIGHT H M Y FUEL SOL OIL PRESSURE SWITCH M START SOL Generator WATERFAULT LOCK OIL FAULT STARTER Wiring c...

Page 25: ...de Company Name 2696 ThoroughClean Address 12 Ashburn Rd Bundamba QLD 4304 Telephone Fax Number Tel 07 5467 2025 Fax 07 5467 2026 Recommended Use Other Names Engine and Pump oil None Listed 2 HAZARDS...

Page 26: ...d clothing and wash before reuse or discard If symptoms develop seek medical attention Eye If contact with the eye s occurs wash with copious amounts of water holding eyelid s open Take care not to ri...

Page 27: ...ing drinking smoking or using toilet facilities Conditions for Safe Storage Store in a cool dry well ventilated area away from heat sources of ignition oxidising agents foodstuffs and clothing and out...

Page 28: ...ratory Protective Devices and AS NZS 1716 Respiratory Protective Devices Eye Protection Safety glasses with side shields goggles or full face shield as appropriate recommended Final choice of appropri...

Page 29: ...TABILITY AND REACTIVITY Chemical Stability Stable under normal conditions Conditions to Avoid Extremes of temperature and contact with incompatibles Incompatible Materials Strong oxidising agents such...

Page 30: ...tis 12 ECOLOGICAL INFORMATION Ecotoxicity No ecological data available for this product Persistence Degradability This material is not expected to be readily biodegradable Mobility Not available Envir...

Reviews: