A convenient line cord latch prevents the power cord disengaging from the unit. The

cord latch is supplied loose and should be fitted before the lightbox is used.

Fig. 3.1   Power supply connection panel

Although the unit is supplied preset for external power connections, power can be

hard wired to the internal PCB as follows:

1) Ensure that the unit is disconnected from mains power.
2) Using a PZ1 screwdriver or other suitable tool, remove the six M3 PoziDriv screws

securing the front panel.

Cautions for Hard Wiring the Unit

The unit should be hard wired only when it is permanently attached to the wall.
Only use 3-core (0.75 to 1.5 mm

2

) 218/318 cable to EN 50525-2-11 to hard wire

the unit.
Grommets with a flammability rating of UL94-V-1 or better must be used at the

cable exit points. Suitable grommets are supplied.
In order to prevent accidental disconnection of cables, ensure that the strain

relief clamp provided is used. The clamp is fitted with two M3 x 6mm screws for

use with standard cable diameters. Two M3 x 8 mm screws are also supplied

for use with larger diameter cables.
A  switch or  circuit  breaker  must  be incl uded  in  the  installation.  It must  be

conveniently located and easily reached, and must be clearly marked as the

disconnecting device for the equipment.

100 - 240 VAC

50/60 Hz

15 W

Summary of Contents for LSS10

Page 1: ...LSS10 LED Lightbox for Laser Safety Signs User Guide Original Instructions...

Page 2: ...1 Control and Connection Overview 8 4 2 Using the Safety Interlock 9 4 3 Replacing the Internal Fuses 10 4 4 Inserting a Laser Safety Sign 10 4 5 Disabling the Brightness Control 11 4 6 Cleaning 11 C...

Page 3: ...2 that prevent the use of interlock equipped laser systems unless the safety light is turned on The external interlock socket accepts a 2 5 mm phono jack supplied The lightbox is permanently fixed to...

Page 4: ...rom electrical shock Warning Given when there is a risk of injury to users Caution Given when there is a risk of damage to the product Note Clarification of an instruction or additional information Wa...

Page 5: ...nd can cause serious injury Appropriate care should be taken when using this device Persons using the device must understand the hazards associated with using high voltages and the steps necessary to...

Page 6: ...s If you are uncertain contact a specialised installer Note The default configuration and labelling is for right handed use however the mounting holes allow the unit to be mounted for left hand use Ca...

Page 7: ...unit should be hard wired only when it is permanently attached to the wall Only use 3 core 0 75 to 1 5 mm2 218 318 cable to EN 50525 2 11 to hard wire the unit Grommets with a flammability rating of U...

Page 8: ...on is disconnected at the next step Fig 3 2 Removing the front panel 4 Unclip the connection to the LED circuit CON4 see Fig 3 3 then remove the panel 5 Ensure mains power is disconnected then move th...

Page 9: ...Fig 3 4 Fig 3 4 Cable knock outs and strain relief clamp locations 7 If using an internal safety interlock perform the procedure detailed in Section 4 2 8 Re connect the LED circuit at CON4 9 Refit th...

Page 10: ...rols overview BRIGHTNESS Used to control the light intensity of the lightbox when the external controls see Section 4 5 are enabled INTLK For use in laser safety applications see Section 4 2 POWER Use...

Page 11: ...ceed 34V DC AC 0 5A and should be electrically isolated from hazardous circuits with reinforced insulation External connection is achieved via the jack socket on the right hand control panel see Fig 4...

Page 12: ...be replaced as follows 1 Remove power from the unit 2 Remove the front panel see Fig 3 2 3 Locate the broken fuse see Fig 3 3 4 Replace the fuse with another of the same type 0 63A T 250 VAC 5 Refit t...

Page 13: ...ternal control is bypassed and brightness is set internally 1 Isolate the unit from mains power 2 Remove the front Panel see Fig 3 2 3 Move switch SW3 to the INT position as shown below Warning The in...

Page 14: ...ghtly dampened with water or a mild detergent Note The MIN setting corresponds to the brightness level set to minimum using the control panel pot Similarly the MAX setting corresponds to the max brigh...

Page 15: ...wer 8W Minimum Brightness to 15 W Max Brightness Internal Fuses Qty 2 0 63A T 250 VAC Operating Temperature Range 5 to 40 C Dimensions W x D x H 362 0 x 257 x 50 mm 14 25 x 10 12 x 1 97 Weight 3 3 Kg...

Page 16: ...harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with th...

Page 17: ...Rev A Nov 2017 Page 15 Chapter 6 Regulatory 6 2 CE Certificate...

Page 18: ...il sales thorlabs com Support techsupport thorlabs com Europe Thorlabs GmbH Hans B ckler Str 6 85221 Dachau Munich Germany Tel 49 0 8131 5956 0 Fax 49 0 8131 5956 99 www thorlabs de Email europe thorl...

Page 19: ...www thorlabs com...

Reviews: