background image

 

 

Installation 

 

 
Clearances 

 

NOTE:  Only non-combustible materials can be used in close proximity to this appliance.

 

 

 

Combustible Surface

 

Non  Combustible  Surface

 

Left / Right Hand Side 

 

Rear

 

250mm 

 

250mm 

 

0mm 

 

0mm

 

 

Assembly 

 

NOTE:

 

 

• This appliance is assembled before delivery except feet. 

 

• This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and 

level. This should be carried out on completion of the gas connection. Refer to the „Gas Connection‟ 
section. 

 

• IM will be stated that the appliance shall be installed in such a way that side body surfaces are not 

accessible in the installed position. 

 

Gas Connection 

 

NOTE:  ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.

 

 

1. 

The Gas Griddles do not require an electrical connection, as they function totally on the gas supply 

only. 

2. 

It is essential that the gas supply is correct for the appliance to be installed and that adequate 

supply pressure and volume are available.  The following checks should therefore be made before 

installation:- 

 

a. Gas Type required for the appliance is shown in the rating label.  Check that this is correct for the gas 

supply the appliance is being installed for.  The gas conversion procedure is detailed in this manual. 

 

b. Supply Pressure required for this appliance is shown in the „Gas supply requirements‟ section of this 

manual. Check the gas supply to ensure adequate supply pressure exists. 

 

c. Input Rate of this appliance is stated on the Rating label .The input rate should be checked against the 

available gas supply line capacity. Particular note should be taken if the appliance is being added to an 
existing installation. 

 

NOTE:  

It is important that adequately sized piping runs directly to the connection joint on the appliance with 

as few tees and elbows as possible to give maximum supply volume. 

 

NOTE:  

Ensure the regulator is converted to the correct gas type that the appliance will operate on. The  

regulator  outlet  pressure  is  fixed  ex-factory  for  the  gas  type . 

 

3. 

Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs so 

that the unit is level and at the correct height. 

4. 

Connect the gas supply to the appliance through the regulator. (refer to the picture of “Install the 

 

Regulator”). A suitable jointing compound which resists the breakdown action of propane must be 

 

used on every gas line connection, unless compression fittings are used. 

5. 

Check all gas connections for leakages. 

 

WARNING:

 

 

DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES. 

 

Summary of Contents for TR-G15F

Page 1: ...vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or deat...

Page 2: ...lation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 8 Operation Guide Lighting the Main Burner Cleaning and Maintenance 12 Routine Maintenance After Each...

Page 3: ...ATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE...

Page 4: ...Natural Gas Propane TR G15F TR G15F Single burner Heat Input 32 5 MJ 32 5 MJ Heat Total 32 5 MJ 32 5 MJ Burner Operating 1 0kPa 2 75kPa Supply Pressure 1 0kPa 2 75kPa Gas Connection BSP BSP The burne...

Page 5: ...4 Dimensions TR G15F...

Page 6: ...djusted by an authorized service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic...

Page 7: ...eing installed for The gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in the Gas supply requirements section of this manual Check the gas su...

Page 8: ...specified in the Operation section of this manual Light the Pilot Burner Light the Main Burner Turning Off the Main Burner Pilot b Ensure that the operator has been instructed in the areas of correct...

Page 9: ...T SEALED BY THE MANUFACTURER SHOULD NOT BE ADJUSTED BY THE USER OPERATOR 1 The Gas Griddles have been designed to provide simplicity of operation and 100 safety protection 2 Improper operation is ther...

Page 10: ...manually light the pilot burner or use the piezo igniter provided optional 3 Release the gas control knob after approximately 10 20 seconds after lighting the pilot burner 4 The pilot burner should s...

Page 11: ...reate air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a su...

Page 12: ...irror like surface OPERATION Turn the burners on about 15 20 minutes before cooking for preheating Set the knobs to the desired flame height or temperature Each valve will control the gas flow to the...

Page 13: ...and prevents damage to the griddle plate surface INITIAL CLEANING Prior to operating your new griddle thoroughly wash the griddle surface and the exterior with a mild detergent or soap solution Do not...

Page 14: ...a qualified service person To achieve the best results cleaning must be regular and thorough and all controls and mechanical parts should be checked and adjusted periodically by a qualified service pe...

Page 15: ...ified service person TOUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE Pilot burner cannot be lit The pilot valve is obstructed Pilot gas turned off pilot valve The pilot valve is bad Fat appears to smoke e...

Page 16: ...ntact your nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part by...

Page 17: ...16 Explosion drawing TR G15F...

Page 18: ...G 01 20 1068637 7 U Burner TR G15F 06 05 1470384 1 8 Griddle Plate Assy TR G15F 06 05 1472746 1 9 Flue Assy TR G15F 06 05 1472727 1 10 L Connector For Manifold TR G15F 01 02 1005351 1 11 Regulator TR...

Page 19: ......

Page 20: ...Please keep this manual in a safe place for future use 15 Badgally Road Campbelltown NSW 2560 Thor after sales service 1300 225 960 V1 Rev2 08 18...

Reviews: